DL6MB Technical Parameter:
| Max. Speed | 6000rpm |
| Max. RCF | 6600×g |
| Max. Capacity | 6×1000ml |
| Timer | 1~9h59min |
| RPM/RCF Convert | Yes |
| Noise (dB) | ≤ 60 |
| Temperature Range | -20~40℃ |
| Acc/Dec | 10 Kinds |
| Speed Accuracy | ±20r/min |
| Temperature Accuracy | ±1℃ |
| Voltage(V/Hz) | AC 220V 50HZ/60HZ |
| Size (L x W x Hmm) | 800×740×930mm |
| Net Weight(Kg) | 310KG |
| Certificates | CE,ISO & Calibration report are available |
Matched Rotors for DL6MB
| Order No. | Rotor | Max Speed (rpm) | Max Volume(ml) | Max.RCF(×g) |
| 6MB-1 | Swing Rotor | 4200 | 6×1000ml | 5100 |
| 6MB-2 | Angle Rotor | 6000 | 4×300ml | 5390 |
| 6MB-3 | Angle Rotor | 6000 | 6×300ml | 5660 |
| 6MB-4 | Angle Rotor | 6000 | 6×500ml | 6600 |
Features
1. Widely used in the field of blood bank, pharmaceutical factory and laboratory.
2. Frequency conversion motor, in great torque, free maintenance, no powder pollution, quick in speed up and down.
3. With pre-cooling function,Digital display which indicates the program, speed, time,RCF, temperature.
4. Micro computer control, there are 10 kinds of program and 10 kinds of acceleration and deceleration for your choice.
5. There are several kinds of rotors for your choice.
6. Electric lid lock, compact design, super speed and imbalance protection.
7. The centrifuge body is made of high-quality steel, safe and reliable.
N-(Propargyl-PEG4)-biocytin is a biotin PEG reagent that is reactive with azide containing molecule via click chemistry. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
N-(Propargyl-PEG4)-biocytin is a biotin PEG reagent that is reactive with azide containing molecule via click chemistry. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Name of Product
Hop Resistance Gene-Screen
Catalog Number
MGScHOR 1
Short Info
This test discovers hop resistance genes in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 cfu/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.
Labelled specific primers are used to amplify specific DNA fragments. In addition to the target gene, a control gene, which is also present in the PCR mixes, is amplified in order to make sure that the PCR process works properly.
The resulting PCR products carry the labels of the incorporated primers.
In a second part of the test, the created PCR products are detected by a lateral flow Test Strip. A “molecular sandwich” is formed and becomes visible as a line on the test Strip.
Brief Instructions
Storage
-15 to -20°C
Components
PCR-Polymerase Master-Mix, PCR-Primermix, Positive Kit-Control, PCR-Water
Name of Product
Hop Resistance Gene-Screen
Catalog Number
MGScHOR 1
Short Info
This test discovers hop resistance genes in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 cfu/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.