This kit provides a rapid spin column procedure for the purification and clean-up of sequencing and various other enzymatic reactions including restriction enzyme digests, Klenow reactions, alkaline phosphatase reactions, and ligations. The kit is used to remove reaction contaminants including dye terminators, salts, enzymes, excess primers and primer dimers. Contaminants are undesirable as they can interfere with many downstream applications including sequencing, RFLP, restriction enzyme digestions and ligation. Purification is based on spin-column chromatography without the use of phenol, chloroform or alcohol precipitation. The kit provides a high quality product with up to 90% recovery.
The kit is also available in a 96-well format for high-throughput sequencing reaction clean-up. Purification with the 96-well plate can be performed using either a vacuum manifold or centrifugation.
Figure 1 / 1
Click for expanded view
| Kit Specifications – 96-well | |
| Binding Capacity Per Well | 15 μg |
| Maximum Loading Volume Per Well | 500 μL |
| Average DNA Recovery | Up to 90% |
| Time to Complete 96 Purifications | 20 minutes |
| Minimum Elution Volume | 50 μL |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
| Component | Cat. 34500 (50 preps) | Cat. 34400 (2 x 96-well plate) |
|---|---|---|
| Binding Buffer C | 30 mL | 3 x 30 mL |
| Wash Solution A | 12 mL | 2 x 20 mL |
| Elution Buffer B | 8 mL | 2 x 15 mL |
| Spin Columns | 50 | – |
| Collection Tubes | 50 | – |
| Elution Tubes (1.7 mL) | 50 | – |
| 96-Well Plate | – | 2 |
| Adhesive Tape | – | 4 |
| 96-Well Collection Plate | – | 2 |
| 96-Well Elution Plate | – | 2 |
| Product Insert | 1 | 1 |
Norgen’s EXTRAClean Plasma/Serum Exosome and Free-Circulating RNA Isolation Kit constitutes an all-in-one system for the purification of exosomes and the sequential isolation of RNA and free-circulating RNA from different plasma/serum sample volumes ranging from 50 μL and up to 10 mL. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. The EXTRAClean columns undergo stringent processing and rigorous quality control measures to minimize contamination traces, ensuring optimal results for sensitive applications such as NGS. The kit is designed to isolate all sizes of RNA, including microRNA. The kit provides a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or any protease treatments. Moreover, the kit allows the user to elute into a flexible elution volume ranging from 50 μL to 100 μL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, NGS application, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Figure 1 / 9
Click for expanded view
| Kit Specifications (Spin Column) | |
| Minimum Plasma Input | 4 mL |
| Maximum Plasma Input | 10 mL |
| Size of RNA Purified | All sizes, including miRNA and small RNA (< 200 nt) |
| Elution Volume | 50-100 μL |
| Time to Complete 10 Purifications | 40-45 minutes |
| Average Yields | Variable depending on specimen |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Name of Product
Milenia GenLine Extraction System
Catalog Number
MGES 1
Short Info
The Milenia GenLine Extraction System is an universal kit which is intended for the isolation of analytes from swabs for further processing.
Method/Platform
Swab Sample Collection System
Range/Assay Sensivity
Test Principle
Brief Instructions
Storage
room temperature
Components
1000 pcs. of reaction tubes (1,5 ml) and 1000 pcs. of mini purification column
Name of Product
Milenia GenLine Extraction System
Catalog Number
MGES 1
Short Info
The Milenia GenLine Extraction System is an universal kit which is intended for the isolation of analytes from swabs for further processing.
Method/Platform
Swab Sample Collection System
Range/Assay Sensivity
Test Principle