This kit provides a convenient and rapid method to purify total RNA from small amounts of stool samples. All types of stool samples can be processed with this kit, including animal fecal samples, manure and samples collected using Norgen’s Stool Nucleic Acid Collection and Transport Devices Dx (Cat. Dx45660). The kit removes all traces of humic acids using rapid and simple spin column procedures. Bead tubes are also provided for effective homogenization of stool. The kit purifies all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA and small interfering RNA. Both host and microbial RNA is recovered. The protocol does not rely on the use of phenol or chloroform, thereby providing a user friendly procedure and allowing high-throughput analysis. The purified RNA is of the highest integrity, and can be used in a number of downstream applications including real time PCR and reverse transcription PCR for gene expression analysis. The procedure can be completed in approximately 30 minutes.
NOTE: This product is not available for sale in the United States.
Figure 1 / 3
Click for expanded view
| Kit Specifications | |
| Maximum Stool Input | 200 mg |
| Type of Stool Processed | Frozen and fresh stool |
| Maximum Column Binding Capacity | 50 μg |
| Maximum Column Loading Volume | 650 μL |
| Time to Complete 10 Purifications | 30 minutes |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
| Component | Cat. Dx49500 (50 preps) |
|---|---|
| Lysis Solution | 60 mL |
| Wash Solution | 22 mL |
| Elution Buffer | 6 mL |
| Bead Tubes | 50 |
| Spin Columns | 50 |
| Collection Tubes | 50 |
| Elution Tubes (1.7 mL) | 50 |
| Product Insert | 1 |
K-MALTA
SKU: 700004315
100 assays (50 of each) per kit
| Content: | 100 assays (50 of each) per kit |
| Shipping Temperature: | Ambient |
| Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
| Stability: | > 2 years under recommended storage conditions |
| Analyte: | α-Amylase, β-Amylase |
| Assay Format: | Spectrophotometer |
| Detection Method: | Absorbance |
| Wavelength (nm): | 400 |
| Signal Response: | Increase |
| Limit of Detection: | 0.05 U/mL |
| Reaction Time (min): | ~ 20 min (Ceralpha Method), ~ 10 min (Betamyl-3 Method) |
| Application examples: | Cereal flours, malts, fermentation broths and other materials. |
| Method recognition: | “Ceralpha” Method: AACC Method 22-02.01, AOAC Method 2002.01, ICC Standard No. 303, RACI Standard Method and CCFRA (Flour Testing Working Group Method 0018). “Betamyl-3” Method: RACI Standard Method |
The Malt Amylase test kit is suitable for the specific measurement and analysis of α-amylase and of β-amylase in malt flour.
Other enzyme activity test kits available.
Advantages
The Malt Amylase test kit is suitable for the specific measurement and analysis of α-amylase and of β-amylase in malt flour.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection of numerous significant pathogens. The genesigPLEX range provides the most efficient method of detecting DNA and RNA by combining multiple assays into a single tube. This principle of multiplexing represents state of the art PCR testing and is a key feature of the high-throughput testing conducted by laboratories around the world. These assays include process controls to verify the quality of the nucleic acid extraction and eliminate false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the handbook.
Packaged, optimised and ready to use. Expect Better Data.
Precise reproducible results
Time saving through completing multiple tests in one go
Cost saving through a reduced price compared with buying four kits separately
Exceptional value for money
Supplied lyophilised – no cold chain shipping