Alkyne-ethyl-PEG1-t-Butyl ester has an alkyne group and a t-butyl protected carboxyl group. The alkyne reacts with azide compounds or biomolecules via copper catalyzed Click Chemistry to form a stable triazole linkage. Thecarboxyl group group can be deprotected under mild acidic conditions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
Alkyne-ethyl-PEG1-t-Butyl ester has an alkyne group and a t-butyl protected carboxyl group. The alkyne reacts with azide compounds or biomolecules via copper catalyzed Click Chemistry to form a stable triazole linkage. Thecarboxyl group group can be deprotected under mild acidic conditions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
32 X 0.2 mL PCR Strip Magnetic Separator
Product Info
Document
Product Info
Permagen’s 32-tube PCR Separation rack features all of the same aspects of our MSR812 rack above for easy protocol transition for labs wishing to scale up to four PCR strips at a time, or up to 32 individual PCR tubes.
Features include solid aluminum alloy design with hard coat finish for years of trouble-free use, rubber feet to help prevent slipping on work bench, less tippy than common plastic products, and fast separations using any magnetic beads
Permagen’s 32-tube PCR Separation rack features all of the same aspects of our MSR812 rack above for easy protocol transition for labs wishing to scale up to four PCR strips at a time, or up to 32 individual PCR tubes.
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from tissue / blood / body fluid / swab /dry blood spots
Applications
PCR, qPCR, southern bolt and virus detection, etc
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot,semen and other clinical samples
Sample amount
Solid tissue: 1-10mg; Anticoagulant blood: 200μl
Elution volume
≥20μl
Time per run
30 – 60 minutes
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Wide applicability- handle a variety of liquid samples
Kit Contents
Contents
D301802
D301803
Purification Times
50
250
HiPure DNA Mini Columns I
50
250
2ml Collection Tubes
100
500
Buffer ATL
30 ml
150 ml
Buffer AL
30 ml
150 ml
Buffer GW1
22 ml
88 ml
Buffer GW2
12 ml
50 ml
Proteinase K
24 mg
120 mg
Protease Dissolve Buffer
1.8 ml
10 ml
Buffer AE
15 ml
60 ml
Storage and Stability
Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
DBCO-C5-NHS ester is an amine-reactive compound, which can be used to modify an amine-containing molecule in organic media. This reagent isn’t soluble in aqueous media. The extended 5-carbon atom spacer arm improves solubility in commonly used organic solvents including dichloromethane, chloroform, THF, and ethyl acetate, and it also improves derivatization efficiency and stability of conjugates. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research use only.
Document
DBCO-C5-NHS ester is an amine-reactive compound, which can be used to modify an amine-containing molecule in organic media. This reagent isn’t soluble in aqueous media. The extended 5-carbon atom spacer arm improves solubility in commonly used organic solvents including dichloromethane, chloroform, THF, and ethyl acetate, and it also improves derivatization efficiency and stability of conjugates. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research use only.