Propargyl-PEG12-methane is a PEG linker that can react with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry to form a stable triazole linkage. The PEG chain enhances the solubility of the molecule in aqueous media. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
Propargyl-PEG12-methane is a PEG linker that can react with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry to form a stable triazole linkage. The PEG chain enhances the solubility of the molecule in aqueous media. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
022210P1 Lauryl Sulfate Tryptose Broth
Product Info
Document
Product Info
Introduction
Usages: Determination of coliform and fecal coliform for multiple tube fermentation.
Principle: Tryptone provide carbon and nitrogen sources to meet the needs of bacterial growth; sodium chloride osmotic pressure balance can be maintained; Lactose is a coliform fermentable sugars; potassium dihydrogen phosphate and dipotassium phosphate is a buffer; lauryl sodium can inhibit the growth of non-coliform bacteria.
How to use: 1. Suspend 35.6g of the product, adding 1 L of distilled or deionized water, heated to boiling stirring until completely dissolved, packed in a test tube with a small down tube, 121 ℃ autoclave 15min, leave to cool to room temperature, standby . 2.Sample handling and dilution. 3.Selected three consecutive dilution, each dilution was inoculated three LST broth tubes, each tube was inoculated 1mL. 4. Put the tubes in an incubator 36 ± 1 ℃ cultured for 48 ± 2h. 5. Observe the results. if all LST broth don’t pruduse gas, can be reported as negative for E. coli, if gas production then will have to make further confirmed by experiments.
Quality control: Quality control strains were inoculated and culuture at 36 ± 1 ℃ for 24h ,results are as follows: Bacterial Name Bacterial No. Growth Status Gassing Escherichia coli ATCC25922 good +
Salmonella typhimurium CMCC (B) 50115 good —
Staphylococcus aureus ATCC6538 inhibited —
Storage: Store in a dark, cool and dry place, tighten the cap immediately after use. Storage period of three years.
The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and templates. The master mix contains a highly stable hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. Consequently, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) features high stability during storage, even at 37°C for weeks. In addition to high sensitivity and signal intensity, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) performs a low background/ high specificity qPCR results, as well as a better compatibility with fast PCR program. With inert smart blue contrast dye, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) also includes ROX reference dye for normalizing the fluorescent reporter signal in real-time quantitative PCR. This master mix allows sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules.
Features
High Stability
Fast Hot Start
High Sensitivity
Low Background
Suitable for Fast Program
Smart Blue Contrast Dye
With ROX Reference Dye
Storage
Protect from light. Aliquot to avoid multiple freeze-thaw cycles. -20°C for 12 months
Document
The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and templates. The master mix contains a highly stable hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. Consequently, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) features high stability during storage, even at 37°C for weeks. In addition to high sensitivity and signal intensity, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) performs a low background/ high specificity qPCR results, as well as a better compatibility with fast PCR program. With inert smart blue contrast dye, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, ROX) also includes ROX reference dye for normalizing the fluorescent reporter signal in real-time quantitative PCR. This master mix allows sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules.
Gel images of different ranges of library size selection. Sheared human genomic DNA was used as input.
.
Library size selection is an enrichment of a specific range of library sizes for NGS library preparations. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads, or SPRI (Solid Phase Reversible Immobilization) beads, is well used for the purification of DNA due to their reversible DNA binding. The NGS library can be size-selected by the magnetic beads or SPRI beads. The properties of the magnetic beads can be changed for a specific range of DNA binding. The contaminants and other unwanted components in the libraries can also be removed during size selection.
Specific ranges of NGS libraries can be selected using magnetic beads with different buffer compositions. The first DNA-beads binding step, also called the right-side clean-up, removes large NGS library fragments. The large NGS library fragments that bind to the beads are discarded with the beads pellet. The desired NGS library fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-DNA binding, also called the left-side clean-up. After the rinsing step, the NGS library fragments with the dual selection are eluted in water or an appropriate buffer. The magnetic beads method has great advantages over time-consuming column purification and tedious gel-based purification.
NGS library size selection with dual clean-ups.
.
Library size selection for long-read sequencing only requires a single clean-up. In this case, only the large library fragments are bound to the beads, while other small library fragments are discarded with the supernatant. The selected larger library fragments are eluted in water or an appropriate buffer after the rinsing step.
NGS library size selection with single clean-up for >5 kb and >10 kb libraries.