DBCO-PEG24-Maleimide is a PEG linker containing a DBCO moiety and a terminal primary maleimide group. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
DBCO-PEG24-Maleimide is a PEG linker containing a DBCO moiety and a terminal primary maleimide group. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
Total RNA Purification Maxi Kit
Product Info
Document
Product Info
Overview
Extract high quality & quantity total RNA including miRNA
No phenol step required – isolate all RNA in one fraction
Rapid processing in under 40 minutes
Isolate total RNA from a wide variety of specimens
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s Total RNA Purification Maxi Kit provides a rapid method for the isolation and purification of total RNA from cultured animal cells, tissue samples, blood, bacteria, yeast, fungi, plants, and viruses. The kit purifies all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA (miRNA) and small interfering RNA (siRNA). The RNA is preferentially purified from other cellular components such as proteins, without the use of phenol or chloroform. The purified RNA is of the highest integrity, and can be used in a number of downstream applications including real-time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Norgen’s Purification Technology
Purification is based on spin column chromatography using Norgen’s proprietary resin as the separation matrix. The RNA is preferentially purified from other cellular components such as proteins without the use of phenol or chloroform. The process involves first lysing the cells or tissue of interest with the provided Buffer RL (please see the flow chart on page 4). Ethanol is then added to the lysate, and the solution is loaded onto a maxi spin column. Norgen’s resin binds RNA in a manner that depends on ionic concentrations. Thus only the RNA will bind to the column, while the contaminating proteins will be removed in the flowthrough or retained on the top of the resin. The bound RNA is then washed with the provided Wash Solution A in order to remove any remaining impurities, and the purified total RNA is eluted with the Elution Solution A. The purified RNA is of the highest integrity, and can be used in a number of downstream applications.
Average Yield: HeLa Cells (5 x 107 cells) E. coli (2.5 x 1010 cells)
~750 μg ~1.5 mg
*For isolating total RNA from purified leukocytes
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
>The display can simultaneously display:all main parameters such as cold trap temperature,vacuum degree,sample temperature, and shelf temperature.
>Schematic diagram of equipment operating components,through graphic display to view the working status of each component of the equipment.
>Ithas the functions of cold trap precooling and vacuum pump preheating,and the time can be set by the userin the system. >Display whether the current running status is normal or not by numerical color.
o One-key operation,the operation is extremely simple,no special professional learning and training is required.
o Thermal electromagnetic over-current and short-circuit protection,making the equipment run more safely and stably.
o Active reminder of equipment maintenance time and vacuum pump replacement lubricating oil time.
o Ambient temperature monitoring,the device automatically reminds the alarm if the ambient temperature is too high.
o Optional eutectic point detection device and endpointjudgment detection system make freeze-drying more scientific.
Dryingchamber
· The separate drying chamber reduces the probability of damage caused byimproper handling of the drying chamber due to height and weight.The upper cover is anodized aluminum with anti-corrosion treatment.●Highly transparent plexiglass drying chamber,good light and heat radiation conduction.Reserve 6/12 external valve ports.· 316L stainless steel all black Teflon coating drying chamber,suitable for drying organic solvents and various corrosive samples,reserved for 6/12 external ports.· 316L stainless steel vertical multi-port multi-manifold external rack(The standard configuration is aplexiglass drying chamber,and one ofthe diying chambers can be optional)
Coldtrapandcondensingcoil
· The cold trap cavity and condensation coil are made of 316L stainless steel.Large opening and channel design,the gas can be quickly captured through the condensing coil.· The cavity and condensing coil are equipped with Teflon anti corrosion coating as standard,which can trap organic solvents and various corrosive solvents.· The condensing coil is placed in the cold trap to increase the condensate catchment area,which can effectively prevent external condensation.
Sampleshelves
· 316Lstainless steel stackable sample shelves,capable oflyophilizing machine solvents and various corrosive solvents.Each shelf can be placed and taken freely without manual work.The distance and height ofeach shelfcan be adjusted freely.-All black coating,good heat absorption performance.-Special hole for freeze-drying of centrifuge tubes,which is conducive to the drying of samples in centrifugetube containers.· All-aluminum Teflon surface anti-corrosion treatment electric heating shelf.
Refrigerationsystem
· Danffos compressorCopper plate heat exchanger,the largest area to increase heat dissipation· Unique refrigeration technology,the temperature of the cold trap can be lowered from ambient temperatureto below-80C°within 2 minutes.· Class A temperature sensor with high temperature accuracy and low error.· Multiple detection and alarm system,the refrigeration system pressure is too high or refrigeration failure cantimely alarm and take corresponding measures.
Techinical parameter
ItemNo
ST7003
ST7006
ST9006
Ice condenser capacity
3kg
6kg
6kg
Ice condenser temperature
-70℃
-70℃
-90℃
Cold trap volume
5L
10L
10L
Freeze dried chamber
Bell shape (standard configuration)/Multi manifold type/T-shaped frame type
Sample shelf
φ200mm.Single layer area 0.03m2 with 3-5 layers available
●260mm/485mm.Single layer area 0.055m²/0.185m².3-10 layers/optional ● Electric heating/manual capping/optiona
Vacuum pump
Extreme vacuum 5*10*mbar with a pumping capacity of 8m³/h optional pump of various types
Oil mist filte
Standard configuration
Vacuum pump connection pipe
Single forming stainless steel flexible pipe DN16 ISO-KF L-1.2m
Anti-corrosive treatment
Cold trap,condensing coil/all equipped with PTFE anti-corrosion treatment as standard. Freeze-drying organic solvents.
External valve
6pieces/optional
1-48 pieces/optional
Eutectic point detection system
Support/Optional
Data output analysis
Support/Optional
Powe
0.6kw
1.1kw
1.5kw
Size
420*545*455mm
510*570*500mm
Document
Freezer Dryer, 3kgs-6kgs water capturer Model: ST7003,ST7006,ST9006
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from tissue / blood / body fluid / swab /dry blood spots
Applications
PCR, qPCR, southern bolt and virus detection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot, semen and other clinical samples
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Wide applicability – It can handle various liquid samples, animal tissues and cultured cells
Kit Contents
Contents
IVD3018
Purification Times
100
HiPure DNA Mini Columns I
100
2ml Collection Tubes
2 x 100
Buffer ATL
60 ml
Buffer AL
60 ml
Buffer GW1
44 ml
Buffer GW2
50 ml
Proteinase K
60 mg
Protease Dissolve Buffer
5 ml
Buffer AE
15 ml
Storage and Stability
Proteinase K should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2–8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
This product is suitable for rapid extraction of total DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.