ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Kits
Facebook
X
Pinterest
Email
Detail
Overview
Columns bind proteins of interest while endotoxins flow through
Reduce endotoxin levels to less than 0.01 EU/µg of protein
Proteins are desalted
Greater than 95% protein recovery
Concentrate protein samples and remove detergents at the same time
Effectively remove a wide range of detergents including SDS, Triton® X-100, CHAPS, NP-40, and Tween 20
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
The ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Kits are designed for the rapid removal of endotoxins from previously purified proteins or peptides, with protein recoveries of > 95% being achieved. Endotoxins, also known as lipopolysaccharides, are cell-membrane components of Gram-negative bacteria such as E. coli. Endotoxins liberated by Gram-negative bacteria are frequent contaminations of protein solutions derived from bioprocesses. Due to the high toxicity of endotoxins in vivo and in vitro, their removal from protein preparations is often necessary prior to the use of the protein in downstream applications. These kits efficiently reduce endotoxin levels to ≤ 0.01 EU/mg of protein, using spin column chromatography based on Norgen’s proprietary resin as the separation matrix. These kits are highly efficient in removing many different salts commonly used in the laboratory including, but not limited to, MgCl2, NaCl, KCl, CaCl2, LiCl and CsCl. The purified protein samples can be used in a number of downstream applications including sequencing, cloning, and in vitro and in vivo introduction into cells and organisms for various purposes. The simultaneous removal of salts while concentrating a dilute protein solution makes the kit a convenient method for preparing proteins before running many downstream applications such as SDS-PAGE, isoelectric focusing, X-ray crystallography, NMR spectroscopy, mass spectroscopy and other applications.
Mini Kit
The ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Mini Kit is designed for the rapid removal of endotoxins from up to 200 μg of previously purified proteins or peptides, with protein recoveries of > 95% being achieved.
Maxi Kit
The ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Maxi Kit is designed for the rapid removal of endotoxins from up to 4 mg of previously purified proteins or peptides, with protein recoveries of > 95% being achieved.
Including Triton® X-100, CHAPS, NP-40 and Tween 20
Elution Volume
2-4 mL
Time to Complete 10 Purifications
30-40 minutes
Storage Conditions All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Component
Cat. 22800 (25 preps)
Cat. 22200 (4 preps)
Binding Buffer J
8 mL
8 mL
Binding Buffer N
4 mL
20 mL
Wash Solution M
50 mL
130 mL
Wash Solution CIP
20 mL
60 mL
Wash Solution N
30 mL
130 mL
Wash Solution NIP
20 mL
60 mL
Elution Buffer G
6 mL
20 mL
Endotoxin Removal Solution
1.5 mL
1.5 mL
Protein Neutralizer EF
2 mL
2 mL
Maxi Spin Columns (assembled with Collection Tubes)
–
4
Mini Spin Columns
25
–
Collection Tubes
25
–
Maxi Spin Columns (assembled with Collection Tubes)
4
Elution Tubes (1.7 mL)
25
–
Elution Tubes (50 mL)
4
–
Product Insert
1
1
Other Products
65L/ 90L/ 110L High-pressure Steam Autoclave
Product Info
Document
Product Info
Safety Features
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.
Isolate and extract high quality & quantity miRNA in 30 minutes
Two column kit- eliminate large RNA on the first column and capture microRNA on a second column
Elute microRNA in 25 µL ready for miRNA profiling
Process a wide range of samples- cell, tissue, bacteria, bodily fluids, etc.
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
This kit provides a rapid method for the isolation and purification of small RNA molecules (< 200 nt) from cultured animal cells, small tissue samples, bacterial cells, plants, and blood.
Two columns are provided with this kit. The first column captures large RNA, while the small RNA are captured on a second column and are eluted concentrated in 25 µL of nuclease-free water.
The small RNA can be used in various downstream applications relating to miRNA profiling, gene regulation, and functional analysis. The eluted RNA is ready for RT-qPCR, microarrays, and NGS applications.
Background
These small RNAs include regulatory RNA molecules such as microRNA (miRNA) and short interfering RNA (siRNA), as well as tRNA and 5S rRNA. Small RNA molecules are often studied due to their ability to regulate gene expression. miRNAs and siRNAs are typically 20-25 nucleotides long and regulate gene expression by binding to mRNA molecules and affecting their stability or translation.
Maximum Amount of Starting Material: Animal Cells Animal Tissues Bacteria Plant Tissues Blood
3 x 106 cells 5-25 mg 1 x 109 cells 50 mg 100 μL
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
N-Boc-N-bis(PEG2-propargyl) enables Click Chemistry reactions with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The Boc-protected amine can be deprotected under acidic conditions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
N-Boc-N-bis(PEG2-propargyl) enables Click Chemistry reactions with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry. The Boc-protected amine can be deprotected under acidic conditions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.