Norgen’s Saliva/Swab RNA Purification Kits provide a rapid method for the purification of total RNA from non-preserved saliva and nasal/throat swabs, and from preserved saliva collected on Norgen’s Saliva RNA Collection and Preservation Devices (Cat. RU53800) or preserved swabs collected in Norgen’s Total Nucleic Acid Preservative Tubes (Cat. 69200). Purification is based on using Norgen’s proprietary resin separation matrix. RNA is preferentially purified from other cellular components such as proteins, without the use of phenol or chloroform. The kit allows the purification of total RNA, including viral and bacterial RNA, irrespective of size or GC content. The purified RNA is eluted in an Elution Solution that is compatible with all downstream applications including PCR, qPCR, methylation-sensitive PCR and Southern Blot analysis, microarrays, and NGS.
Saliva/Swab RNA Purification Kit (Spin Column)
This kit offers a range of elution volumes, with a minimum elution volume of 75 μL and a maximum elution volume of 100 μL. Complete 10 purifications in as little as 15 minutes.
High throughput 96-well plate format for rapid purifications with very consistent well-to-well RNA isolation. Purified RNA is suitable for a variety of downstream applications , including Small RNA Sequencing. Find out more information about Norgen’s NGS Services.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
150 reactions
Urine Exfoliated Cell and Bacteria RNA Purification Kit
Product Info
Document
Product Info
Overview
Purify all sizes of RNA (including microRNA) without the need for phenol
Isolate and detect total RNA from 1 mL and up to 50 mL urine
Provides high-quality RNA for sensitive applications – isolate RNA from as little as 100 cells
Rapid processing time from sampling to downstream testing
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
This kit provides a rapid spin column method for the isolation and purification of total RNA (including microRNA) from exfoliated cells that have been shed into the urine from the urinary tract. The kit purifies all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA (miRNA) and small interfering RNA (siRNA). The RNA is preferentially purified from other cellular components such as proteins, as well as from the contaminating species found in urine such as glucose and salts, without the use of phenol or chloroform. The purified RNA is of the highest integrity and can be used in a number of downstream applications including real-time RT-PCR, qRT-PCR, Northern blotting, NGS, and expression array assays. Multiple samples can be processed in 20 minutes.
Background
RNA biomarkers from exfoliated cells can be used as non-invasive tools for a number of diagnostic and research applications including the diagnosis and monitoring of bladder, kidney, or other urinary-tract cancers.
~1μg RNA per 1 x 105 cells (For Exfoliated Cells – Varies due to cell density sample)~0.5μg RNA per 1 x 107 cells(For Bacteria – Varies due to cell density sample)
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.