Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
Detail
Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.
Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.
Other Products
TG18 Tabletop 21000rpm High Speed Low Speed Non-refrigerated Large Capacity Multi-purpose lab centrifuge 800ml /500ml bottles & 5/7/10/15/50ml tubes
Product Info
Document
Product Info
TG18 Tabletop 21000rpm High Speed Low Speed Non-refrigerated Large Capacity Multi-purpose lab centrifuge 800ml /500ml bottles & 5/7/10/15/50ml tubes. And holding Angle Rotors like 24×1.5/2ml, 6x50ml, 12x15ml…in high speed separation smooth.
It’s widely used in the field of animal and plant molecular biology, which is the ideal instrument for seperating the chemical substances in the cell and purifing the microorganisms, viruses, bacteira and subcelluar etc.
TG18 High Speed/Low Speed Centrifuge Features:
1. Max. Speed 21000rpm, max. volume 4x800ml, can be used for 5ml/10ml/15ml/30ml/50ml/100ml centrifuge tubes.
2. Brushless DC motor in great torque, no powder pollution, free maintenance, quick in speed up and down.
3. Can store 10 programs, automatically calculate and synchronously display the RCF data. Digital display indicates the speed, time, temperature and RCF. The parameters can be changed in operation, no need to stop the centrifuge which is quite convenient.
4. The centrifuge body is made of high-quality steel, and with high-quality steel centrifuge chamber, safe and reliable.
5. Automatically electric lid lock, over speed/over temperature protection and imbalance protection.
6. There are many kinds of rotors for your choice, both in high speed and low speed.
TG18 High Speed/Low Speed Centrifuge Technical Parameters:
Max. Speed
21000rpm
Max. RCF
30910xg
Max. Capacity
4x800ml
Timer
0-99min
Speed Accuracy
±20rpm
Noise(DB)
≤65DBA
Voltage(V/HZ)
AC220V/110V,50HZ 10A
Dimension(LxWxHmm)
685x500x385mm
Net Weight(Kg)
70KG
Certificates
CE, ISO
Warranty
1 Year
TG18 High Speed/Low Speed Centrifuge Matched Rotors:
Order No.
Rotor Type
Max Speed(r/min)
Volume(ml)
Max. RCF(xg)
G18-1
Swing Rotor
4000
4x800ml
3450
G18-2
Microplate Rotor
4000
4x4x96well
2940
G18-3
Microplate Rotor
4000
2x4x96well
3210
G18-4
Microplate Rotor
4000
2x3x48well
2300
G18-5
Swing Rotor
4000
4x30x5ml vacuum tube
2840
G18-6
4x30x7ml vacuum tube
3140
G18-7
4x18x10ml vacuum tube
3140
G18-8
Swing Rotor
4000
Fat bottle
3830
G18-9
Fixed Rotor
16000
4x8PCR
15760
G18-10
Fixed Rotor
15000
6x8PCR
21420
G18-11
Fixed Rotor
16000
8x8PCR
17480
G18-12
Fixed Rotor
15000
12x8PCR
22930
G18-13
Fixed Rotor
15000
40×0.5ml
22920
G18-14
Fixed Rotor
21000
12×1.5/2ml
30910
G18-15
Fixed Rotor
16000
24×1.5/2ml
23440
G18-16
Fixed Rotor
14000
30×1.5/2ml
20800
G18-17
Fixed Rotor
13000
48×1.5/2ml
17930
G18-18
Fixed Rotor
16000
16x5ml
22020
G18-19
Fixed Rotor
16000
6x10ml
21500
G18-20
Fixed Rotor
15000
12x10ml
22680
G18-21
Fixed Rotor
13000
16x10ml
19490
G18-22
Fixed Rotor
13000
8x15ml
17790
G18-23
Fixed Rotor
11000
12x15ml
14330
G18-24
Fixed Rotor
5000
24x15ml
3500
G18-25
Fixed Rotor
5000
30x15ml
3830
G18-26
Fixed Rotor
14000
6x30ml
19060
G18-27
Fixed Rotor
13000
6x50ml(conical)
18840
G18-28
Fixed Rotor
13000
6x50ml(round)
18730
G18-29
Fixed Rotor
5000
12x50ml
3860
G18-30
Fixed Rotor
4000
24x50ml
2970
G18-31
Fixed Rotor
13000
4x85ml
18940
G18-32
Fixed Rotor
12000
4x100ml
14850
G18-33
Fixed Rotor
10000
6x100ml
11380
G18-34
Fixed Rotor
4000
12x100ml
2970
G18-35
Fixed Rotor
12000
24 capillaries
15800
G18-36
Swing Rotor
15000
4x5ml
19920
G18-37
Vertical Rotor
16000
16x5ml
16540
G18-38
Vertical Rotor
14000
8x30ml
19750
The Corners of our Company____________________________________
Usages: For count, isolation and cultivation of mould and yeast.
Principle: Peptone provides the carbon and nitrogen; glucose to provide energy; potassium dihydrogen phosphate as a buffer; agar as medium coagulant; chloramphenicol inhibit the growth of bacteria; Bengal as selective antibacterial agents inhibit the growth of bacteria.
How to use: 1.Suspend 31.6g in 1 L of distilled water , stirring heated to boiling until completely dissolved, dispensing flask, 121 ℃ autoclave for 15min. 2.Diluted and treated samples.
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light. Storage period of 3 years.
Isolate genomic DNA from all types of bacteria (both Gram-positive and Gram-negative)
Rapid and convenient spin column protocol
96-well format available for high throughput
High yield, high quality DNA for sensitive downstream applications including sequencing, PCR, qPCR and more
This kit is designed for the rapid spin column preparation of genomic DNA from 2 x 109 viable bacterial cells (between 0.5 and 1.0 mL of culture). This kit can be used for both Gram-negative and Gram-positive bacteria including Escherichia coli and Bacillus cereus. Purified genomic DNA is of an excellent quality and yield, and is fully compatible with restriction enzyme digestions, sequencing, PCR, qPCR and more. Also available in 96-well format for high throughput applications.
* Yield will vary depending on the type of sample processed
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. The kit contains a ready-to-use Proteinase K, which is dissolved in a specially prepared storage buffer. The buffered Proteinase K is stable for up to 2 years after the date of shipment when stored at room temperature.