The Opentrons Flex Waste Chute GEN1 occupies position D3 and is used to accept waste such as tips, tip racks, and plates in high volumes. The gripper will pick up the consumable and dispose it into the chute based on your workflow needs. The waste chute is neccesary for all high-throughput workflows and can be paired with the Opentrons Flex Deck Expansion Set to maximize the throughput capabilities of the Opentrons Flex. The following consumables can disposed of into the waste chute:
– NEST 2 mL Deep Well Plate, V Bottom
– Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt
– NEST 96 well Plate Flat
– All Opentrons Flex tip racks
Detail
The Opentrons Flex Waste Chute GEN1 occupies position D3 and is used to accept waste such as tips, tip racks, and plates in high volumes. The gripper will pick up the consumable and dispose it into the chute based on your workflow needs. The waste chute is neccesary for all high-throughput workflows and can be paired with the Opentrons Flex Deck Expansion Set to maximize the throughput capabilities of the Opentrons Flex. The following consumables can disposed of into the waste chute:
– NEST 2 mL Deep Well Plate, V Bottom
– Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Glucose, Raffinose, Sucrose
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
510
Signal Response:
Increase
Limit of Detection:
100 mg/L
Reaction Time (min):
~ 20 min
Application examples:
Analysis of grain legumes and other materials containing raffinose, stachyose and verbascose.
Method recognition:
Used and accepted in food analysis
The Raffinose/Sucrose/D-Glucose test kit is for the measurement and analysis of D-glucose, sucrose and raffinose, stachyose and verbascose in seeds and seed meals. Based on the measurement of D-glucose on enzymic hydrolysis of raffinose, stachyose and verbascose to D-glucose, D-fructose and D-galactose.
All reagents stable for > 2 years after preparation
Simple format
Rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Document
The Raffinose/Sucrose/D-Glucose test kit is for the measurement and analysis of D-glucose, sucrose and raffinose, stachyose and verbascose in seeds and seed meals. Based on the measurement of D-glucose on enzymic hydrolysis of raffinose, stachyose and verbascose to D-glucose, D-fructose and D-galactose.
Everything you need to run a trial PACE® allele-specific PCR Genotyping Reaction on your existing lab equipment. Each PACE Trial Kit includes Test DNA samples, PACE Genotyping Assays, PACE Master Mix and a comprehensive PACE Genotyping Trial Kit Manual.
WHO IS THIS TRIAL KIT FOR?
Anyone who wants to try PACE genotyping reagents in their lab for the first time with a set of validated DNA samples, SNP assays and PACE Master Mix.
TRIAL KIT OVERVIEW
Step 1. Dispense each of the three trial DNA samples (DNA 1, 2 and 3) plus water (No Template Control) in triplicate onto a PCR plate using the suggested volumes.
Step 2. Combine appropriate volumes of PACE Genotyping Master Mix with PACE Genotyping Assay in a tube, as directed, then mix.
Step 3. Dispense the combined mixtures into each of the wells containing DNA using volumes indicated. Each test now contains a complete PACE Genotyping Reaction.
Step 4. Seal your PCR plate with an optically clear seal and centrifuge to ensure all components are at the bottom of the wells.
Step 5.Thermally cycle the reaction plate using the thermal cycling conditions provided.
Step 6. Read the plate and compare data produced with the expected results provided in the manual. Simple!
PACE MECHANISM
More information on the PACE genotyping chemistry and how it works can be found here: www.3crbio.com/#pace. PACE allele-specific PCR is used for the detection of SNPs, Indels and other sequence variants.
REQUIRED COMPONENTS
qPCR machine or Thermocycler + Fluorescent plate reader
PCR plate or equivalent and appropriate optically clear seal