Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected*. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Other Products
OT-2 20µL Tips
Product Info
Document
Product Info
Opentrons OT-2 Tips, 20µL. Optimized for volumes 1µL to 20µL. Clear Tips, Polypropylene. These tips are DNAse/RNAse, pyrogen and protease free – they are sterilized from ebeam irradiation. Not autoclavable.
Compatible with: Opentrons 8-Channel GEN2 P20 Electronic Pipettes, Opentrons Single-Channel GEN2 P20 Electronic Pipettes, Opentrons Single-Channel GEN1 P10 Electronic Pipettes, Opentrons 8-Channel GEN1 P10 Electronic PipettesOpentrons platform and workstation accuracy and precision performance is not validated with use of non-Opentrons tips.
Document
Opentrons OT-2 Tips, 20µL. Optimized for volumes 1µL to 20µL. Clear Tips, Polypropylene. These tips are DNAse/RNAse, pyrogen and protease free – they are sterilized from ebeam irradiation. Not autoclavable.
Compatible with: Opentrons 8-Channel GEN2 P20 Electronic Pipettes, Opentrons Single-Channel GEN2 P20 Electronic Pipettes, Opentrons Single-Channel GEN1 P10 Electronic Pipettes, Opentrons 8-Channel GEN1 P10 Electronic PipettesOpentrons platform and workstation accuracy and precision performance is not validated with use of non-Opentrons tips.
Adenovirus Purification from any input – cell fraction or media fraction
Rapid purification within 2 to 4.5 hours
No specialized equipment needed (ultracentrifuge not required)
Purify adenovirus cell culture supernatant from 1 mL to 33.5 mL input per prep
Purify adenovirus cell pellet from 1 mL of input per prep
Up to 25X sample concentration
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Adenoviral vectors are useful tools for both in vitro and in vivo gene transfer, and oncolytic viruses based on adenovirus are highly promising for cancer treatment. Norgen’s Adenovirus Purification Kit provides a fast and simple procedure for concentrating and purifying adenoviral vectors from cell lysate and cell culture media. Purification is based on spin column chromatography using Norgen’s proprietary resin as an ion exchanger. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. Adenoviral vectors purified in this manner are highly active for use in transduction experiments.
Norgen’s Adenovirus Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit.
At least 3×1011 adenovirus particles as determined by qPCR At least 3×108 transducing units as determined by transduction assay
Input type
Cells, media
Input volume (Supernatant)
1 – 33.5 mL SN per prep (500 mL SN in total)
Input Volume (Cell pellet)
1 mL cell pellet per prep (15 mL in total)
Minimum elution volume
1.3 mL per prep
Time to complete purification
2.5 to 4.5 hours with 1 hour hands on time
In vivo transduction
Yes
Storage Conditions and Product Stability
HL-SAN Nuclease should be stored at -20°C upon arrival. Elution Buffer P should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Galactose, Raffinose
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
4 to 83 µg of D-galactose per assay (i.e. approx. 12 to 250 µg of raffinose per assay)
Limit of Detection:
21 mg/L
Reaction Time (min):
~ 60 min
Application examples:
Cereal flours, soybean flour, by-products of sucrose manufacture and other materials.
Method recognition:
Used and accepted in food analysis
The Raffinose/D-Galactose test kit allows for the specific and rapid measurement of raffinose and D-galactose in plant materials and food products.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).