Attogene’s Cadmium Lateral Flow Kit can be used to detect Cadmium in the field.
Format: 10 test cassettes
Run Time: 15 Minutes
Cadmium contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Cadmium accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking cadmium-contaminated food and water include numerous negative health effects. Attogene’s Cadmium Lateral Flow test gives results conforming of 5ppb or greater.
Other Products
HybriDetect Cassette
Product Info
Document
Product Info
Name of Product
HybriDetect Cassette
Catalog Number
MGHC 1
Short Info
The HybriDetect Cassette is the cassette version of our HybriDetect dipstick (MGHD 1). It is a simple and quick tool to develop your own rapid test and allows you and your clients a custumor friendly evaluation. Various molecules can be detected such as proteins, antibodies and genetic amplicons.
Please note, that you may have to pay country-specific taxes and duties.
Method/Platform
Lateral flow, sandwich or competetive
Range/Assay Sensivity
10 pmol/LFA – 1 fmol/LFA
Test Principle
Milenia HybriDetect Cassette is a ready-to-use, universal test unit, which is based on the lateral flow technology using gold nanoparticles. The test unit is designed to develop qualitative or semi-quantitative rapid test systems for several analytes such as proteins, antibodies, or gene amplicons. The user needs to develop an analyte-specific solution or reaction (PCR, RPA, LAMP, CRISPR/Cas, …), which contains a first detector (e.g. antibody, antigen, specific probe) labelled with FITC or FAM and a second one (e.g. antibody, primer) labelled with biotin.
Document
The HybriDetect Cassette is the cassette version of our HybriDetect dipstick (MGHD 1). It is a simple and quick tool to develop your own rapid test and allows you and your clients a custumor friendly evaluation. Various molecules can be detected such as proteins, antibodies and genetic amplicons.
[PM2610] ExcelBand™ Enhanced 3-color High Range Protein Marker (9-245 kDa), 250 μl x 2
Product Info
Document
Product Info
Description
The PM2610/PM2611 ExcelBand™ Enhanced 3-color High Range Protein Marker is a ready to use three-color protein standard with 12 pre-stained proteins covering a wide range of molecular weights from 10 to 245 kDa in Tris-Glycine buffer (9 to 235 kDa in BisTris (MOPS) buffer and 10-235 kDa in Bis-Tris (MES) buffer). Proteins are covalently coupled with different chromophores for easy identification of bands, with two reference proteins carrying enhanced intensity corresponding to a green at 25 kDa and red at 75 kDa, respectively, as separated on SDS-PAGE (Tris-Glycine buffer). The ExcelBand™ Enhanced 3-color High Range Protein Marker is designed for monitoring protein separation during SDS-polyacrylamide gel electrophoresis, verification of Western transfer efficiency on membranes (PVDF, nylon, or nitrocellulose) and for approximating the size of proteins.
Features
Ready-to-use — Premixed with a loading buffer for direct loading, no need to boil.
Two reference bands — 75 kDa (red) and 25 kDa (green)
Contents
Approximately 0.2~0.6 mg/ml of each protein in the buffer (20 mM Tris-phosphate (pH 7.5 at 25°C), 2 % SDS, 3.6 M Urea, and 15 % (v/v) Glycerol).
Quality Control
Under suggested conditions, the PM2610/PM2611 Enhanced 3-color High Range Protein Marker resolves 12 major bands in 15% SDS-PAGE (Tris-Glycine buffer, MOPS, and MES buffer) and after Western blotting to nitrocellulose membrane.
Storage
4°C for 3 months -20°C for long term storage
Document
The PM2610/PM2611 ExcelBand™ Enhanced 3-color High Range Protein Marker is a ready to use three-color protein standard with 12 pre-stained proteins covering a wide range of molecular weights from 10 to 245 kDa in Tris-Glycine buffer (9 to 235 kDa in BisTris (MOPS) buffer and 10-235 kDa in Bis-Tris (MES) buffer). Proteins are covalently coupled with different chromophores for easy identification of bands, with two reference proteins carrying enhanced intensity corresponding to a green at 25 kDa and red at 75 kDa, respectively, as separated on SDS-PAGE (Tris-Glycine buffer). The ExcelBand™ Enhanced 3-color High Range Protein Marker is designed for monitoring protein separation during SDS-polyacrylamide gel electrophoresis, verification of Western transfer efficiency on membranes (PVDF, nylon, or nitrocellulose) and for approximating the size of proteins.