Primer and probe mix (150 reactions)
Reverse Transcription, target specific primers (RNA genome viruses only)
Copy number standard curve (sufficient for multiple standard curves)
Internal extraction control – Read through VIC channel*
Endogenous control (150 tests)
RNAse/DNAse free water
*alternative fluorophores available on request
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Other Products
High-speed lab mixer for microplates & tubes
Product Info
Document
Product Info
Compact and stylish designed, the BioShake XP high-speed microplate mixer lets you perform all your standard mixing runs with a minimum of adjustments. The XP offers outstanding performance to handle a wide range of applications across biotechnology, pharmaceutical and academic research.
Small. Light. Efficient. Quiet.
Ideal for microplates & PCR plates
High-precision mixing from 200 up to 3,000 rpm
Universal spring clamps for easy fixation
Wide range of adapters
Stylish, fire resistant aluminium housing
ADVANCED TECHNOLOGY
Compact & stylish designed
Mixing tasks in microplates can be realized fast & safe with using adjustable speed of 200 up to 3,000 rpm.
The BioShake mixing-technology is obviously more robust, vibration free and needs less maintenance compared to classical mixers.
The first-class finished aluminium housing gives the BioShake XP its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
GENTLE MIXING OF SAMPLES
By planar orbital motion
German designed and manufactured, BioShake XP plate mixer offer an ultra-efficient, 2-dimensional shaking axis so that samples mix completely in a fraction of the time of competing systems.
The mixing orbit of 2.0 mm is always constant. The orbital shaking is precisely controlled, in fact, that you need never spin down your plates after mixing. Even tubes, vials, high density plates, or low sample volumes, offer no obstacle for these precision tools.
Fully adjustable between 200 rpm and 3,000 rpm, well beyond the speeds of most other brands, guarantees fast, splatter-free, mixing for tubes, glass vials or across an entire 384-well microplate.
COMFORT
Simple intuitive operation and programming
The BioShake XP is operated from the front face of the enclosure which includes touch buttons and a display.
Special buttons for start, stop and storage of time and mixing modes enable the instrument to run complex applications. This opens new points of view on the daily laboratory work and optimizes routine application enormously.
The short mix button allows short and fast mixing in between.
The two line LCD display guarantees simultaneous and safe reading of all programmed and measured parameters as time and mixing frequency.
UNIVERSAL SPRING CLAMPS
Suitable for all microplates
In the corners eight spring clamps are inserted for easy fixation of skirted microplates anddeep well plates in SBS format 127.7 x 85.5 mm without an attached adapter. These spring clamps lock the microplate quickly and safely, even at the highest mixing frequencies.
For flexible and deformable PCR plates we recommend using of the related PCR adapter.
Fast mixing processes with frequent plate changes can be performed in the routine as easy and safe.
UNIQUE DESIGN MEETS HIGH-END TECHNOLOGY
First-class finished aluminium housing
Unique and efficient design combined with the most compact housing result in beautiful and well-defined laboratory equipment. Therefore, the first-class finished aluminium housing gives the BioShake XP its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
Safety of the user and ease of use are clearly a priority for us.
EXCHANGABLE ADAPTERS
For a wide range of applications
The BioShake XP comes with a variety of standardized and specific adapter plates. The replacement of the adapters are very simple.
Perfect shaped adapters allow an optimal fit for standard tubes, lysis tubes, microplates, glass vials and other sample vessels.
MADE IN GERMANY
High-end instruments for daily routine
A perfectly harmonious blend of high-tech and handmade. “Made in Germany” has always been a recipe for success for QInstruments. 100% of QInstruments production takes place in Germany.
The focus is on human diligence and on being environmentally friendly. The company upholds its quality guarantee by means of consistent quality management. For more than 15 years these lab automation professionals from Jena have used only high-quality materials to ensure sustainable production, applied innovative thinking and undertaken research in a future-oriented way – all as a matter of course.
Document
Ideal for microplates & PCR plates
High-precision mixing from 200 up to 3,000 rpm
Universal spring clamps for easy fixation
Wide range of adapters
Stylish, fire resistant aluminium housing
HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.
Details
Specifications
Features
Specifications
Main Functions
Recover DNA fragments between 20bp-20kbp from crude DNA and enzymatic reaction solution
Applications
PCR, sequencing, labeling reactions, ligations and restriction digestion, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Crude DNA, enzymatic reaction solution
Sample amount
<150μl
Recovery
80%
Elution volume
≥15μl
Time per run
≤10 minutes
Liquid carrying volume per column
800µl
Binding yield of column
20µg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gelslices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
High recovery efficiency – up to 80% DNA recovery
Fast – isolation can be completed in 10 minutes by column gel method
Low elution volume – elution volume can be as low as 10μl
Efficient – efficient removal of various inhibitory factors
Kit Contents
Contents
D214102
D214103
Purification Times
100 Preps
250 Preps
Buffer GWP
30 ml
60 ml
Buffer DW2
20 ml
50 ml
Elution Buffer
30 ml
60 ml
HiPure DNA Mini Columns I
50
250
2 ml Collection Tubes
50
250
Storage and Stability
HiPure DNA Clean Up Kit components are guaranteed for at least one year when stored at room temperature. If any precipitates form in the buffers, warm at 37℃ to dissolve.
Document
HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.
TDL5E Bench top low speed refrigerated centrifuge machine
Product Info
Document
Product Info
TDL5E Bench top low speed refrigerated centrifuge machine
Application:
Widely used in the field of biochemistry, biological products, pharmaceutical factory and laboratory.
TDL5E Technical Parameters:
Max. Speed
5000rpm
Max.RCF
4420xg
Max. Volume
4x180ml
Speed Accuracy
±20rpm
Timer
1~99h59min
Noise
≤60dBA
Dimension(LxWxHmm)
570x600x340mm
Net Weight
76Kg
Power Supply
AC220V/110V 50HZ/60HZ
Temperature Range
-20℃~40℃
Temperature Accuracy
±1℃
Certifications
CE, ISO & Calibration report is available.
Matched Rotors for TDL5E:
Order No.
Rotor Type
Max. Speed(rpm)
Volume(ml)
Max.RCF(xg)
5E-1
Swing rotor
4000
4x180ml
2580
5E-2
Microplate rotor
4000
2x3x96well
2020
5E-3
Swing rotor
5000
4x1x50ml
4420
5E-4
Swing rotor
5000
4x1x100ml
4420
5E-5
Swing rotor
4000
4x2x50ml
2820
5E-6
Swing rotor
4000
4x4x15ml
2820
5E-7
Swing rotor
4000
4x6x10/7ml
2580
5E-8
Swing rotor
4000
4x6x5ml
2170
5E-9
Swing rotor
4000
4x4x10/7ml
2580
5E-10
Swing rotor
4000
4x4x5ml
2170
5E-11
Fixed rotor
5000
6x15ml
2540
5E-12
Fixed rotor
5000
12x15ml
3080
5E-13
Fixed rotor
5000
24x15ml
3500
5E-14
Fixed rotor
5000
4x50ml
2520
5E-15
Fixed rotor
5000
6x50ml
2850
5E-16
Fixed rotor
5000
4x100ml
2630
5E-17
Fixed rotor
5000
6x100ml
3130
Document
TDL5E is a table top low speed refrigerated centrifuge widely used in the field of biochemistry, biological products, pharmaceutical factory and laboratory.