Lupus test – La antigen lateral flow serology test. Rapidly detect antibodies targeting the human La autoantigen. 10 tests per kit.
About La: The La autoantigen has been implicated to be important for many different cellular processes including RNP maturation, internal ribosome-entry-site-mediated translation, mRNA stabilization, and transcription termination. La binds to the poly U tracts of polymerase III precursor RNAs and certain polymerase II transcribed RNAs.
Attogene La antigen serology test can be used to detect autoantibodies targeting the La Protein found in human Sera and differentiate IgG and IgM.
Features:
1.Brushless frequency motor,in great torque, free maintenance, no powder pollution, quick in speed up and down.
2.Imported compressors fluorine free,double cycle cooling,cold and hot alternating easily, free environment pollution and precise in temperature control.
3. Microprocessor control, digital display which indicates the speed, time, RCF in operation, speed raising and reducing quickly, operate simply. Running parameter can be edited.
4. 10 kinds of program stored in the memory, 10 kinds of accelerating and decelerating speed for your choice.
5. Automatically electric lid lock, super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
6. Rotor is connected to spindle by specialized taper sleeve, loading simple and quick, no direction.
7. There are several kinds of rotors for your choice, adapters can be designed by experimental requirements.
8. 3 tiers protection steel cover and get the ideal centrifugation result.
TDL5M Technical Parameter:
| Max. Speed | 5000rpm |
| Max. RCF | 4730×g |
| Max. Capacity | 4×800ml( 4*450ml blood bags) |
| Time Range | 0~99h59min |
| RPM/RCF Convert | Yes |
| Noise (dB) | ≤ 65 |
| Temperature | -20℃-40℃ |
| Acc/Dec | 10 Kinds |
| Speed Accuracy | ±20r/min |
| Temperature Accuracy | ±1℃ |
| Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
| Size (W x D x Hmm) | 700×715×420mm |
| Net Weight(Kg) | 125KG |
| Certificates | CE,ISO & Calibration report are available |
Matched Rotors for TDL5M
| Order No. | Rotor | Max Speed (rpm) | Max Volume(ml) | Max. RCF(×g) |
| NO30671 | Swing Rotor | 4000 | 4×800ml(Round Cup) | 3450 |
| NO30696 | Swing Rotor | 4000 | 4×500ml( Round Cup) | 3380 |
| NO30679 | Swing Rotor | 4000 | 4×500ml(Square Cup) | 3310 |
| NO31494 | Microplate Rotor | 4000 | 4×4×96 Well | 2840 |
| NO31491 | 4000 | 2×4×96 Well | 2490 | |
| NO31376 | 4000 | 2×3×48 Well | 2300 | |
| NO30690 | Swing Rotor | 4000 | 4×30×7ml | 3270 |
| 4×30×5ml | 2890 | |||
| 4×18×10ml | 3140 | |||
| NO30607 | Angle Rotor | 5000 | 12×15ml | 3080 |
| NO30611 | Angle Rotor | 5000 | 6×50ml | 2850 |
| NO30640 | Angle Rotor | 5000 | 4×50ml | 2520 |
| NO30613 | Angle Rotor | 5000 | 4×100ml | 2630 |
| NO30639 | Angle Rotor | 5000 | 24×15ml | 3500 |
| NO30641 | Angle Rotor | 5000 | 12×50ml | 3860 |
| NO30614 | Angle Rotor | 5000 | 6×100ml | 3130 |
| NO30642 | Angle Rotor | 4000 | 12×100ml | 2970 |
Adapter for 800ml and 500ml bucket
| 5ml | 7ml | 10ml | 15ml | 50ml | |
| 800ml(Round Cup) | 23pcs/cup | 23 | 19 | 14 | 5 |
| 500ml(Round Cup) | 18pcs/cup | 18 | 14 | 9 | 3 |
| 500ml(Square Cup) | 20pcs/cup | 20 | 16 | 12 | 5 |
West Nile Virus (WNV) belongs to the RNA virus family of Flaviviridae. It is known to spread primarily through arthropod vectors such as mosquitoes. The virus infects mainly birds but is also reported to infect humans as well as pets such as cats and dogs. In humans, the majority of the infections caused by WNV are asymptomatic. However, some individuals (the majority of the confirmed cases) could enter a second, febrile stage with flu-like symptoms – commonly known as West Nile Fever. In a more serious stage, the disease becomes neuroinvasive, causing meningitis or encephalitis. Such severe conditions could lead to mortality. As the symptoms of WNV are very similar to other common diseases but can be fatal at a severe stage, it is important to distinguish the virus early in the diagnosis, particularly at the molecular level.
WNV TaqMan RT-PCR Kit, 100 reactions
WNV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
| Component | Cat. TM44250 (100 preps) | Cat. TM44210 (100 preps) |
|---|---|---|
| MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
| WNV Primer & Probe Mix | 280 μL | 280 μL |
| WNV Positive Control | 150 μL | 150 μL |
| Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
| Product Insert | 1 | 1 |