Description
Specifications
Clone | IHC580 |
Source | Mouse Monoclonal |
Positive Control | Pituitary |
Dilution Range | 1:200 |
Follicle-Stimulating Hormone (FSH) allows for progression of ovarian folliculogenesis, and enables Sertoli cell proliferation in the testis. Anti-FSH reacts with FSH-producing cells, therefore FSH staining is useful for classifying pituitary cancers and understanding pituitary disease.
Clone | IHC580 |
Source | Mouse Monoclonal |
Positive Control | Pituitary |
Dilution Range | 1:200 |
Permagen’s 15 mL/ 50 mL Centrifuge Tube Magnetic Combo rack is designed for magnetic bead separations from up to three each, 15 mL or 50 mL Centrifuge tubes
Accommodates any common 15 mL Centrifuge Tubes and or 50 mL Centrifuge Tubes
Beads will be pulled to back wall allowing easy aspiration and tip tracking down the front wall of the tubes without disturbing bead pellet
Features include solid aluminum alloy design with hard coat finish for years of trouble-free use, rubber feet to help prevent slipping on work bench, less tippy than common plastic products, and fast separations using any magnetic beads
MSR1550
Maximum Volume – 50 mL (50 mL Tube)
Minimum Volume – 7 mL (15 mL Tube)
Permagen’s 15 mL/ 50 mL Centrifuge Tube Magnetic Combo rack is designed for magnetic bead separations from up to three each, 15 mL or 50 mL Centrifuge tubes
This kit provides a single tube to screen for the presence of high-risk HPV types, HPV16, HPV18, HPV31, HPV33, HPV35, HPV39, HPV45, HPV51, HPV52, HPV56, HPV58, HPV59, HPV66 and HPV68. The multiplex test is detected in two fluorescent channels differentiating between HPV16 / HPV18 which both produce a VIC channel signal and all others which produce a signal in the FAM channel. HPV16 and HPV18 account for 70% of positive findings in clinical practice so it is helpful to know if either of these are present. All other high risk genotypes together make up the remaining 30% of clinical positives and are grouped together into the FAM channel. In this configuration, the kit gives a partial genotyping result and some additional information on which high risk strains are present.
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
PACE OneStep RT-PCR Master Mix combines reverse transcription (RT) and PCR in a single reaction. This advanced master mix simplifies workflows by eliminating the need for separate reactions for reverse transcription of RNA to cDNA, and PCR amplification from the newly generated cDNA. PACE OneStep RT-PCR Master Mix is highly efficient and sensitive, enabling detection of low-abundance RNA targets, particularly useful for applications such as gene expression analysis and viral RNA detection. PACE OneStep RT-PCR Master Mix demonstrates robust performance across a wide range of RNA templates and can be employed for both routine and challenging samples.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map