Description
Specifications
| Clone | IHC002 |
| Source | Mouse Monoclonal |
| Positive Control | Breast Carcinoma |
| Dilution Range | 1:200 |
The Her2/Neu (c-erbB-2) proto-oncogene is a transmembrane receptor tyrosine kinase that is clinically indicated in a number of carcinomas. Overexpression of the c-erbB-2 protein has been associated with ductal breast cancer, as well as pulmonary and gastric adenocarcinomas. A correlation between Her2 and p53 has also been documented, as overexpression of both proteins has been associated with early invasion and metastasis in bladder cancer.

| Clone | IHC002 |
| Source | Mouse Monoclonal |
| Positive Control | Breast Carcinoma |
| Dilution Range | 1:200 |
Description
The DM3160 FluoroBand™ 1KB (0.25-10 kb) Fluorescent DNA Ladder is a ready-to-use DNA ladder, which is pre-mixed with high sensitivity DNA binding fluorescent dye and loading dye for direct gel loading. The DNA ladder DM3160 is composed of 13 individual DNA fragments: 10k, 8k, 6k, 5k, 4k, 3k, 2.5k, 2k, 1.5k, 1k, 750, 500, and 250 bp derived from a mixture of PCR products and specifically digested plasmid DNA; these bands can be visualized when illuminated with 470 nm blue light or UV light. This product contains two enhanced bands (3 kb and 1 kb) for easier reference. In addition, two tracking dyes, Xylene cyanol FF and Bromophenol blue which mimic the migration of 4,000 bp and 500 bp dsDNA during electrophoresis are also added for real time monitoring. Real time observation of the electrophoresis is also possible if compatible light source is fitted to the electrophoresis tank.
Features
Source
Phenol extracted PCR products and dsDNA digested with specific restriction enzymes, equilibrated in 10 mM Tris-HCl (pH 8.0) and 10 mM EDTA.
Range
250 ~ 10,000 bp
Concentration
50 µg/ 500 µl
Recommended loading volume
5 µl/ well
Storage
Protected from light
Room temperature for 6 months
4°C for 12 months
-20°C for 24 months
The DM3160 FluoroBand™ 1KB (0.25-10 kb) Fluorescent DNA Ladder is a ready-to-use DNA ladder, which is pre-mixed with high sensitivity DNA binding fluorescent dye and loading dye for direct gel loading. The DNA ladder DM3160 is composed of 13 individual DNA fragments: 10k, 8k, 6k, 5k, 4k, 3k, 2.5k, 2k, 1.5k, 1k, 750, 500, and 250 bp derived from a mixture of PCR products and specifically digested plasmid DNA; these bands can be visualized when illuminated with 470 nm blue light or UV light. This product contains two enhanced bands (3 kb and 1 kb) for easier reference. In addition, two tracking dyes, Xylene cyanol FF and Bromophenol blue which mimic the migration of 4,000 bp and 500 bp dsDNA during electrophoresis are also added for real time monitoring. Real time observation of the electrophoresis is also possible if compatible light source is fitted to the electrophoresis tank.
Hydrolysis probe genotyping master mix for use with 5’ nuclease assays such as TaqMan™, BHQ®, BHQplus® & Zen™ probes. Accurate, robust performance at competitive prices.
ProbeSure Master Mix combines class-leading performance with the most competitive prices in the market. ProbeSure Master Mix has provided users with accurate, robust, and consistent performance for many years. It has been carefully optimised to work over a wide range of reaction volumes and sample template qualities.
ProbeSure Master Mix is supplied at 2x concentration for convenience and is supplied with the ROX normalising dye at either high level (500 nM final concentration), low level (25 nM final concentration) or without ROX.
Hydrolysis probe genotyping master mix for use with 5’ nuclease assays such as TaqMan™, BHQ®, BHQplus® & Zen™ probes. Accurate, robust performance at competitive prices.
Cell Washer/Serofuge Centrifuge
Features
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, laboratory and biochemistry.
2. Brushless motor, free maintenance, no powder pollution, quick in speed up and down.
3. Special program, HLA and SERO separately.
5. Micro computer control system, LED display the RCF,time and speed.
6.. Electric lid lock, compact design, super speed and imbalance protection.
TD4 Technical Parameter:
| Max. Speed | 4000rpm |
| Max. RCF | 2000 |
| Max. Capacity | 12×7 |
| Time Range | 0~99min |
| RPM/RCF Convert | Yes |
| Noise (dB) | ≤ 55 |
| Temperature | Normal |
| Acc/Dcc | 10 Kinds |
| Speed Accuracy | ±20r/min |
| Temperature Accuracy | / |
| Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
| Size (W x D x Hmm) | 485×320×255mm |
| Net Weight(Kg) | 24KG |
Matched Rotors for TD4
| Order No. | Rotor | Max Speed (rpm) | Max Volume(ml) | Max. RCF(×g) |
| NO31501 | SERO Rotor | 3000 | 12×7/5ml(10-13*60-100mm) | 2000 |
| NO31502 | HLA Rotor | 4000 | 12×2/1.5/0.5ml | 1000 |
| Rotor Name | Max RCF(×g) | Use |
| HLA rotor for Lymphocyte washing | 2000 | Lymphocyte separation incubated cell separation |
| 1000 | Hematoblast extenterate(thrombin disposal) | |
| 1000 | Lymphocyte washing | |
| SERO rotor for erythrocyte washing | 500 | Blood type determination, the image of the hematocyte |
| 1000 | The test of intersectant aptness | |
| 1000 | Hematocyte washing, the distillation of the serum and plasma |
TD4 cell washer centrifuge it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, laboratory and biochemistry.