Description
Specifications
Clone | IHC969 |
Source | Mouse Monoclonal |
Positive Control | Thyroid Gland |
Dilution Range | 1:200 |
Tau proteins are abundant in neurons of the central nervous system, and function in microtubule stability and organization. Defects in Tau functioning and aggregation of these proteins have been clinically linked to a number of neurodegenerative disorders including Alzheimer’s disease, Parkinson’s disease, Pick’s disease (PiD), progressive supranuclear palsy (PSP), cortical basal degeneration (CBD), and frontotemporal dementia with parkinsonism linked to chromosome 17 (FTDP-17).
Clone | IHC969 |
Source | Mouse Monoclonal |
Positive Control | Thyroid Gland |
Dilution Range | 1:200 |
ProbeSure Multiplex Master Mix is an enhanced version of ProbeSure Master Mix, formulated to enable users to analyse up to four targets in one reaction well. For example, two bi-allelic SNPs or one reference gene and a further three genes of interest.
Users will require a plate reader capable of reading FAM, HEX, ATTO 550, ATTO 647N and ATTO 633 (the wavelengths of each of these can be found in our ProbeSure Multiplex Master Mix User Guide). ProbeSure Multiplex Master Mix is supplied at 2x concentration for convenience and is supplied with the ATTO 633 normalising dye at either high level (500 nM final concentration), low level (25 nM final concentration) or without ATTO 633.
K-GCROL
SKU: 700004292
70 assays (manual) / 700 assays (microplate)
Content: | 70 assays (manual) / 700 assays (microplate) |
Shipping Temperature: | Ambient |
Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
Stability: | > 2 years under recommended storage conditions |
Analyte: | Glycerol |
Assay Format: | Spectrophotometer, Microplate |
Detection Method: | Absorbance |
Wavelength (nm): | 340 |
Signal Response: | Decrease |
Linear Range: | 0.8 to 35 µg of glycerol per assay |
Limit of Detection: | 0.34 mg/L |
Reaction Time (min): | ~ 5 min |
Application examples: | Wine (and grape juice), beer, spirits, vinegar, marzipan, fruit juices, soft drinks, toothpaste, honey, tobacco, paper (and cardboard), cosmetics, pharmaceuticals, soap and other materials (e.g. biological cultures, samples, etc.). |
Method recognition: | Methods based on this principle have been accepted by OIV and MEBAK |
The Glycerol test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of Glycerol in beverages, foodstuffs and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Browse our wide range of alcohol assay kit products.
Advantages
The Glycerol test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of Glycerol in beverages, foodstuffs and other materials.
Our SNPsig® kits use our own proprietary genotyping method to enable the identification of SARS-CoV-2 variants of concern. These products can be used on any real-time PCR machine using familiar protocols, whilst resulting in exceptional genotyping data.
Positive control templates for wild-type and variants are supplied in every kit to make data interpretation simple.
SNPsig® EscapePLEX™ SARS-CoV-2 also incorporates the two gene (ORF1ab and M Gene) assay to provide a confirmatory detection of SARS-CoV-2.
DETECTION PROFILE: The E484K, K417N, K417T and P681R mutations which are found in Beta, Gamma, Delta and Delta Plus Variants of Concern
Rapid detection of specific detection profiles
High priming efficiency
Sensitive to < 100 copies of target
Positive copy number standard curve for quantification
Accurate controls to confirm findings
96 reactions