Description
Specifications
Clone | IHC072 |
Source | Mouse Monoclonal |
Positive Control | Lung Adenocarcinoma |
Dilution Range | 1:200 |
Tumor-Associated Glycoprotein 72 (TAG-72) is a glycoprotein found on the surface of many cancer pathologies. Anti-TAG-72 can be useful for detecting some adenocarcinomas and non-neoplastic tissues. This diagnostic grade TAG-72 IVD antibody is useful for identifying adenocarcinomas in positive staining, but in mesotheliomas no staining is observed.
Clone | IHC072 |
Source | Mouse Monoclonal |
Positive Control | Lung Adenocarcinoma |
Dilution Range | 1:200 |
Product advantages
1. The instantaneous centrifugal function rises to the maximum speed for about 6 seconds, allowing for rapid detachment of hanging droplets from the wall;
2. Faster acceleration and deceleration rate, required to complete the experiment in a shorter time;
3. Door cover protection, overspeed and imbalance detection system, capable of real-time monitoring of the centrifugal process, ensuring the safe operation of the instrument; When the operation ends, an error occurs, or an imbalance occurs, the sound signal prompts, and the operation stops at the same time. The LCD displays the result code
Host Parameters
Product model | Mini-3 |
Input power supply | DC24V/2.75A |
Input power | 55W |
Motor/Drive Method | DC24V brushless DC variable frequency motor |
Display method | High brightness LCD screen |
Effective centrifugal time | 1-99min.1-59sec |
speed | 300~3000±15rpm |
Speed step increase | 10rpm |
Maximum capacity | 2 *96 well PCR plates/ELISA plates |
MAX. RCF | 608 xg |
Misoperation/alarm failure | Sound prompt+display code |
weight | 3.9Kg |
Noise | 60dB (A) |
Fastest acceleration time | <6s |
Fastest deceleration time | <5s |
Permissible ambient temperature/relative temperature | +5-40°C/80% |
The micro porous plate centrifuge adopts international advanced design concepts and manufacturing technology, with a smooth and beautiful appearance, compact and stable structure, adhering to the advantages of high universality and easy operation. It also has the functional characteristics of “smooth start” and “smooth braking”; This micro porous plate centrifuge is very suitable for 96 or 384 well and small capacity micro porous plates, as well as various standard PCR micro porous plates with or without skirts .
Hydrolysis probe genotyping master mix for use with 5’ nuclease assays such as TaqMan™, BHQ®, BHQplus® & Zen™ probes. Accurate, robust performance at competitive prices.
ProbeSure Master Mix combines class-leading performance with the most competitive prices in the market. ProbeSure Master Mix has provided users with accurate, robust, and consistent performance for many years. It has been carefully optimised to work over a wide range of reaction volumes and sample template qualities.
ProbeSure Master Mix is supplied at 2x concentration for convenience and is supplied with the ROX normalising dye at either high level (500 nM final concentration), low level (25 nM final concentration) or without ROX.
Hydrolysis probe genotyping master mix for use with 5’ nuclease assays such as TaqMan™, BHQ®, BHQplus® & Zen™ probes. Accurate, robust performance at competitive prices.
Cryptosporidium is a parasite found in water that causes an infection in mammals termed cryptosporidiosis. It is one of the most common water-borne diseases and is found world-wide. It affects the intestines of mammals and typically causes an acute short-term infection. The most common symptom is self-limiting diarrhea in healthy individuals, however in immunocompromised individuals the symptoms are particularly severe and often fatal. There is no specific treatment for cryptosporidiosis other than fluid rehydration and management of any pain. Therefore early detection of Cryptosporidium in water is the foremost action to prevent the infection.
Cryptosporidium TaqMan RT-PCR Kit, 100 reactions
Cryptosporidium TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component | Cat. TM39150 (100 preps) | Cat. TM39110 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
Cryptosporidium Primer & Probe Mix | 280 μL | 280 μL |
Cryptosporidium Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio