Permagen’s 24 x 1.5 mL Microcentrifuge tube magnetic separation plate was designed specifically for large volumes either manually or on a robotic platform from 1.5 mL tubes. Same layout as a 24-Microplate for easy integration
Detail
Permagen’s 24 x 1.5 mL Microcentrifuge tube magnetic separation plate was designed specifically for large volumes either manually or on a robotic platform from 1.5 mL tubes. Same layout as a 24-Microplate for easy integration
SBS SLAS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
Silicone oil thermal conductive shelf, high-precision processing method of upper and lower clamping, shelf temperature uniformity can reach ±0.5°c
Integrated cavity:
Integrated chamber, the shelf and cold trap are located in the same chamber, the steam conduction is faster and the freeze-drying effect is better
Refrigerating and heating control system:
Using thermally conductive silicone oil with a high temperature range and precise PID control algorithm, the control accuracy can reach ±0.5°C. Sample shelf temperature range: -70°C~ +80°C
Freeze-drying endpoint testing system:
The pressure comparison method is used to determine the freeze-drying end point. The freeze-drying end point test can be automatically performed after the analytical drying stage to ensure that the moisture content of the material reaches the standard requirements.
Vacuum precise control and adjustment system:
The sublimation and analytical drying processes are controlled and adjusted with high precision to make the freeze-drying process warmer and the sample sublimation more reliable.
Pulse backfill system:
Three backfilling modes can be selected: slow, medium and fast, which avoids the problem of effective substances being blown away and lost due to the aeration of granular and flocculent materials after freeze-drying.
Manual automatic mode selection:
Manual mode is used to explore process parameters (strong human intervention), automatic mode is used in the mature stage of the process, one-click operation, simple and convenient
Data recording and analysis system:
Through the PC host computer, all operating parameters and background parameters of the equipment can be recorded in real time, and all parameter action changes and action changes of operating components can be recorded.
Freeze-drying process recipe storage function:
The host can store 60 sets of fixed or user-defined freeze-drying process recipes, and the PC can store >10,000 programs (depending on the computer hard drive)
Eutectic point test function:
The eutectic point temperature of the product can be tested offline and online, and the spectrum can be analyzed manually or automatically (optional)
Remote control system:
The operating status of the device can be monitored remotely, and the device can be monitored in real time via WiFi or the cloud.
Mobile phone monitoring system:
You can monitor the operating status of the equipment with your mobile phone, which is simple and convenient (optional)
Cold trap defrost system:
The hot air defrosting method has high safety performance; the defrosting speed is fast, which solves the inconvenience caused by traditional immersion defrosting.
Plasma/Serum Exosome Purification and RNA Isolation Kits
Product Info
Document
Product Info
Overview
Purification and enrichment of intact plasma/serum exosomes for functional studies
Isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias
Versatile plasma/serum input volume
No phenol extractions, Proteinase K treatment, nor carrier RNA required
No time-consuming ultracentrifugation, filtration nor special syringes required
No precipitation reagents, nor overnight incubation required
Compatible with plasma/serum from most species
Pure exosomes are purified and are free from any other RNA-binding proteins
Purification is based on spin column chromatography that uses Norgen’s proprietary resin
The purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Norgen’s Plasma/Serum Exosome and RNA Isolation Kits constitute all-in-one systems for the purification of exosomes and the sequential isolation of exosomal RNA from different plasma/serum sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias. These kits provide a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Norgen’s Plasma/Serum Exosome and RNA Isolation Mini Kit
For sample volumes ranging from 50 µL to 1 mL. This kit allows the user to elute into a flexible elution volume ranging from 50 µL to 100 µL.
Norgen’s Plasma/Serum Exosome and RNA Isolation Midi Kit
For sample volumes ranging from 1 mL to 4 mL. This kit allows the user to elute into a flexible elution volume ranging from 50 µL to 100 µL.
Norgen’s Plasma/Serum Exosome and RNA Isolation Maxi Kit
For sample volumes ranging from 4 mL to 10 mL. This kit allows the user to elute into a flexible elution volume ranging from 50 µL to 100 µL.
All sizes, including miRNA and small RNA (< 200 nt)
Elution Volume
50-100 μL
Time to Complete 10 Purifications
35 – 40 minutes
Average Yields
Variable depending on specimen
*Please check page 4 of the product insert for the average yields and the common RNA quantification methods
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note This kit is suitable for the purification of exosomes from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.