Norgen’s Total RNA Purification Kits Dx provide rapid methods for the isolation and purification of total RNA from tissue samples, blood, plasma, serum, saliva, bacteria, yeast, fungi and viruses for subsequent in vitro diagnostic use. Extract high quality and purity RNA with excellent RIN values and A260/A280 suitable for downstream applications including qRT-PCR, RT-PCR, microarrays, NGS and more.
Total RNA Purification Kit Dx (Spin Column)
This kit is designed to be used with any downstream application employing enzymatic amplification or other enzymatic modifications of RNA followed by signal detection or amplification. Any diagnostic results generated using the RNA isolated with Norgen’s Total RNA Purification Kit Dx in conjunction with an in vitro diagnostic assay should be interpreted with regard to other clinical or laboratory findings.
Total RNA Purification 96-Well Kits Dx (High Throughput and High Throughput Deep Well)
Thess 96-well kits provide a rapid method for the high-throughput isolation and purification of total RNA in 30 minutes using vacuum manifold, plate centrifuge, or liquid handlers with vacuum capabilities. Total RNA can be isolated from a broad range of sample sources including cultured cells, tissues, blood, serum, plasma, bacteria, yeast, fungi, and viruses.
Intended Use
To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used. Norgen’s Total RNA Purification Kits Dx are intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques. Norgen’s Total RNA Purification Kits Dx do not provide a diagnostic result. It is the sole responsibility of the user to use and validate the kit in conjunction with a downstream in vitro diagnostic assay.
NOTE: This product is not available for sale in the United States.
Figure 1 / 13
Click for expanded view
Kit Specifications | |
Maximum Binding Capacity Per Well | 50 μg |
Maximum Loading Volume Per Well | 500 μL |
Size of RNA Purified | All sizes, including small RNA < 200 nt |
Time to Complete 96 Purifications | 30 minutes |
Average Yield HeLa Cells (1 x 106 Cells) E. coli (1 x 109 cells) Brain (10 mg) Liver (10 mg) Blood (50 μL, Hamster) | 15 μg 50 μg 9 μg 26 μg 1 μg |
Maximum Amount of Starting Material: Whole Blood Plasma/Serum Bacteria Yeast Fungi Plant Tissue | 100 µL150 µL1 x 109 cells1 x 108 cells 40 mg 40 mg |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. These reagents should remain stable for at least 1 year in their unopened containers.
Component | Cat. Dx17200 (50 preps) | Cat. Dx24300 (192 preps) | Cat. Dx24350 (192 preps) | Cat. Dx24380 (576 preps) |
---|---|---|---|---|
Lysis Solution | 40 mL | – | – | – |
Buffer RL | – | 2 x 40 mL | 2 x 40 mL | 350 mL |
Wash Solution | 22 mL | – | – | – |
Wash Solution A | 22 mL | 2 x 38 mL | 2 x 38 mL | 1 x 148 mL 1 x 74 mL |
Elution Solution | 6 mL | – | – | – |
Elution Solution A | – | 2 x 20 mL | 2 x 20 mL | 60 mL |
Mini Spin Columns | 50 | – | – | – |
96-Well Isolation Plate | – | 2 | 2 | – |
96-Well Isolation Plate (Deep Well) | – | – | – | 6 |
Collection Tubes | 50 | – | – | – |
96-Well Collection Plate | – | 2 | 2 | – |
96-Well Collection Plate (Deep Well) | – | – | – | 6 |
Elution Tubes (1.7 mL) | 50 | – | – | – |
96-Well Elution Plate | – | 2 | 2 | – |
96-Well Elution Plate (Deep Well) | – | – | – | 6 |
Adhesive Tape | – | 4 | 4 | 12 |
Product Insert | 1 | 1 | 1 | 1 |
Description
The ExcelDye™ 6× DNA Loading Dye (Orange) is pre-mixed buffer for tracking the DNA sample during the electrophoresis on agarose or polyacrylamide gels. It contains one dye (Orange G) for tracking the DNA migration. The Orange G migrates at approximately 30 bp on a standard 2% TAE agarose gel (50 bp on 1% TAE agarose gel). The included glycerol keeps the DNA at the bottom of the well and the presence of EDTA chelates divalent metal ions to prevent the process of metal-dependent nuclease.
Composition
Storage
4°C for 12 months
-20°C for 36 months
The ExcelDye™ 6× DNA Loading Dye (Orange) is pre-mixed buffer for tracking the DNA sample during the electrophoresis on agarose or polyacrylamide gels. It contains one dye (Orange G) for tracking the DNA migration. The Orange G migrates at approximately 30 bp on a standard 2% TAE agarose gel (50 bp on 1% TAE agarose gel). The included glycerol keeps the DNA at the bottom of the well and the presence of EDTA chelates divalent metal ions to prevent the process of metal-dependent nuclease.
General information
Champion™ Competent Cells are chemically competent cells, which were prepared by SMOBIO to make E. coli perform excellent transformation efficiency. Standard transformation protocol is recommended for large plasmids or non-ampicillin selection. Time-saving transformation protocol is recommended for simple and rapid transformation. Champion™ Competent Cells are one of the fastest and simplest ready-to-use competent cell products in the world.
Kit contents
Shipping condition
Throughout the shipping process, the temperature is maintained under -70°C.
Storage and expiration
Champion™ Competent Cells must be stored between -70°C to -80°C. Subsequent freeze-thaw cycles will reduce transformation efficiency. If high efficiency is required for the experiment, do not use aliquots that have gone through several freeze-thaw cycles. The efficiency of Champion™ Competent Cells lasts for 1 year with proper storage.
Champion™ Competent Cells are chemically competent cells, which were prepared by SMOBIO to make E. coli perform excellent transformation efficiency. Standard transformation protocol is recommended for large plasmids or non-ampicillin selection. Time-saving transformation protocol is recommended for simple and rapid transformation. Champion™ Competent Cells are one of the fastest and simplest ready-to-use competent cell products in the world.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map