

Norgen’s Candida albicans TaqMan PCR Lyophilized Kit is designed for the detection of Candida albicans specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s Candida albicans TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of Candida albicans specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Figure 1 / 3
Click for expanded view
| Component | Cat. TM34050L (100 preps) | Cat. TM34010L (100 preps) |
|---|---|---|
| MDx TaqMan 2X PCR Master Mix (Lyo) | 4 x 350 μL | – |
| Candida albicans Primer & Probe Mix (Lyo) | 280 μL | 280 μL |
| Candida albicans Positive Control (Lyo) | 150 μL | 150 μL |
| Nuclease-Free Water (Negative Control) | 3 x 1.25 mL | 1 x 1.25 mL |
| Product Insert | 1 | 1 |
Name of Product
Megasphaera/Pectinatus Screen
Catalog Number
MGScMP 1
Short Info
GenLine discovers beer germs in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 KBE/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.
Labelled specific primers are used to amplify specific DNA fragments. In addition to the target gene, a control gene, which is also present in the PCR mixes, is amplified in order to make sure that the PCR process works properly.
The resulting PCR products carry the labels of the incorporated primers.
In a second part of the test, the created PCR products are detected by a lateral flow Test Strip. A “molecular sandwich” is formed and becomes visible as a line on the test Strip.
Brief Instructions
The entire procedure of the test can be divided into 3 different steps.
Storage
-15 to -20°C
Components
PCR-Polymerase Master-Mix, PCR-Primermix, Positive Kit-Control, PCR-Water
Name of Product
Megasphaera/Pectinatus Screen
Catalog Number
MGScMP 1
Short Info
GenLine discovers beer germs in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 KBE/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.
Mastitis is the single most costly disease of dairy cattle resulting in the reduction of milk yield and quality. The inflammation of the utter is mainly caused by infection of various bacteria. Streptococcus dysgalactiae, a Lancefield group C α-hemolytic gram-positive bacteria, is a common pathogen in subclinical and clinical mastitis causing substantial economic losses in dairy herds. Streptococcus dysgalactiae has been isolated from infected mammary glands and teat injuries and is transmitted primarily during milking. However, detection of S. dysgalactiae in other cow tissues such as tonsils, mouth and vagina, and occurrence of S. dysgalactiae mastitis during the non-lactating period in herds, suggests that the organism also behaves as an environmental pathogen.
Streptococcus dysgalactiae TaqMan PCR Kit, 100 reactions
Streptococcus dysgalactiae TaqMan PCR Probe/Primer Set and Controls, 100 reactions
For research use only and NOT intended for in vitro diagnostics.
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
| Component | Cat. TM30750 (100 preps) | Cat. TM30710 (100 preps) |
|---|---|---|
| MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
| S. dysgalactiae Primer & Probe Mix | 280 μL | 280 μL |
| S. dysgalactiae Positive Control | 150 μL | 150 μL |
| Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
| Product Insert | 1 | 1 |