Description
- Appearance: White/blue
- • Length of strip: 85mm
- • Width of strip: 5mm
- • Length of device: 140mm
- • Width of device: 15mm
West Nile Virus (WNV) belongs to the RNA virus family of Flaviviridae. It is known to spread primarily through arthropod vectors such as mosquitoes. The virus infects mainly birds but is also reported to infect humans as well as pets such as cats and dogs. In humans, the majority of the infections caused by WNV are asymptomatic. However, some individuals (the majority of the confirmed cases) could enter a second, febrile stage with flu-like symptoms – commonly known as West Nile Fever. In a more serious stage, the disease becomes neuroinvasive, causing meningitis or encephalitis. Such severe conditions could lead to mortality. As the symptoms of WNV are very similar to other common diseases but can be fatal at a severe stage, it is important to distinguish the virus early in the diagnosis, particularly at the molecular level.
WNV TaqMan RT-PCR Kit, 100 reactions
WNV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
Component | Cat. TM44250 (100 preps) | Cat. TM44210 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
WNV Primer & Probe Mix | 280 μL | 280 μL |
WNV Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |
Features
1. Widely used in the field of pharmaceutical factory and laboratory.
2. Brushless frequency motor, in great torque, free maintenance, no powder pollution, quick in speed up and down.
3. Digital display which indicates the program, speed, time,RCF, temperature.
4. Micro computer control, there are 10 kinds of program and 10 kinds of acceleration and deceleration for your choice.
5. Several rotors for your choice.
6. Electric lid lock, compact design, super speed and imbalance protection.
7. The centrifuge body is made of high-quality steel, safe and reliable.
GL10 Technical Parameter:
Max. Speed | 10000rpm |
Max. RCF | 15730×g |
Max. Capacity | 6×1000ml |
Time Range | 1~9h59min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 65 |
Temperature | -20~40℃ |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Voltage(V/Hz) | AC 380V/220V 50HZ/60HZ |
Size (W x D x Hmm) | 800×740×930mm |
Net Weight(Kg) | 360KG |
Certificates | CE,ISO & Calibration report are available |
Matched Rotors for GL10
Order No. | Rotor No. | Max Speed (rpm) | Max Volume(ml) | Max.RCF(×g) |
G10-1 | Angle Rotor | 8000 | 6×1000ml | 14550 |
G10-2 | Angle Rotor | 9000 | 6×500ml | 14860 |
G10-3 | Angle Rotor | 10000 | 6×300ml | 15730 |
G10-4 | Swing Rotor | 4200 | 6×1000ml | 5100 |
MagPure Stool DNA Kit is specially designed for high throughput DNA extraction from stool samples. It can get high purity microbial DNA from stool samples (≤200mg). This kit is based on magnetic beads purification and unique inhibiting factors adsorption technology, no phenol-chloroform extraction or alcohol precipitation. It can adsorb humic acid and other inhibiting factors in the solution efficiently. DNA can be directly used for downstream applications such as PCR, Viral DNA testing, bacterial DNA testing, etc.
Specifications
Features | Specifications |
Main Functions | Isolation total DNA from 100-150mg stool samples |
Applications | PCR, southern blot and enzyme digestion, etc. |
Purification technology | Magnetic beads technology |
Process method | Manual or automatic |
Sample type | Stool |
Sample amount | 100-150 mg |
Elution volume | |
Time per run |
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Lysozyme. DNA is released into the lysate. After adding magnetic particles and binding solution, DNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA was eluted by Elution Buffer.
Kit Contents
Contents | D636401 | D636402 | D636404 |
Purification Times | 48 Preps | 96 Preps | 400 Preps |
MagPure Particles N | 1.7 ml | 3.4 ml | 14 ml |
2ml Bead Tubes | 48 | 96 | 400 |
RNase A | 10 mg | 20 mg | 75 mg |
Proteinase K | 24 mg | 48 mg | 180 mg |
Protease Dissolve Buffer | 3 ml | 5 ml | 20 ml |
Buffer ATL | 60 ml | 110 ml | 300 ml |
PVP-10 | 1.2 g | 2.2 g | 6 g |
Buffer PCI | 50 ml | 100 ml | 300 ml |
Buffer MLE | 30 ml | 60 ml | 180 ml |
Buffer GW1* | 22 ml | 44 ml | 132 ml |
Elution Buffer | 20 ml | 20 ml | 60 ml |
Storage and Stability
MagPure Particles, RNase A and Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
MagPure Stool DNA Kit is specially designed for high throughput DNA extraction from stool samples. It can get high purity microbial DNA from stool samples (≤200mg). This kit is based on magnetic beads purification and unique inhibiting factors adsorption technology, no phenol-chloroform extraction or alcohol precipitation. It can adsorb humic acid and other inhibiting factors in the solution efficiently. DNA can be directly used for downstream applications such as PCR, Viral DNA testing, bacterial DNA testing, etc.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand