Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

D2141 HiPure DNA Clean Up Kit

Facebook
X
Pinterest
Email

HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.

Detail

Introduction

HiPure DNA Clean Up Kit usesproprietary chemistry and HiPure technology to recover DNA Fragments between20bp-20kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing,restriction digestion, or various labeling reactions. In addition, this kit canbe also used to recover DNA directly from enzymatic reactions such as PCR andenzyme digestion reactions.

Details

Specifications

FeaturesSpecifications
Main FunctionsRecover DNA fragments between 20bp-20kbp from crude DNA and enzymatic reaction solution
ApplicationsPCR, sequencing, labeling reactions, ligations and restriction digestion, etc.
Purification methodMini spin column
Purification technologySilica technology
Process methodManual (centrifugation or vacuum)
Sample typeCrude DNA, enzymatic reaction solution
Sample amount<150μl
Recovery80%
Elution volume≥15μl
Time per run≤10 minutes
Liquid carrying volume per column800µl
Binding yield of column20µg


Principle

The HiPure system uses a simple bind-wash-elute procedure. Gelslices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.

Advantages

  • High recovery efficiency – up to 80% DNA recovery
  • Fast – isolation can be completed in 10 minutes by column gel method
  • Low elution volume – elution volume can be as low as 10μl
  • Efficient – efficient removal of various inhibitory factors

Kit Contents

ContentsD214102D214103
Purification Times100 Preps250 Preps
Buffer GWP30 ml60 ml
Buffer DW220 ml50 ml
Elution Buffer30 ml60 ml
HiPure DNA Mini Columns I50250
2 ml Collection Tubes50250

Storage and Stability

HiPure DNA Clean Up Kit components are guaranteed for at least one year when stored at room temperature. If any precipitates form in the buffers, warm at 37℃ to dissolve.

Other Products

120×7ml Swing Buckets Rotor 

Human Papillomavirus (HPV) 6/16 TaqMan PCR Detection Kits

Overview

  • Detection kits for the HPV 6/16
  • Available in TaqMan format for analysis

More than 70 types of human papillomavirus (HPV) have been identified, and are generally classified as high-risk or low-risk depending on their relationship or lack of relationship with cancer and high-grade cervical intraepithelial neoplasia (CIN 2-3). HPV viruses are predominantly sexually transmitted and high-risk HPV types are a major risk factor for development of cervical cancer. HPV 16 has been considered as a high-risk cancer associated HPV type. The low-risk HPV type 6 has been associated with the presence of genital warts. There are many other low-risk HPV types that are not associated with genital warts or cervical cancer. Until now, HPV cannot be cultured in vitro, and immunological tests are inadequate to determine the presence of HPV cervical infection. On the other hand, biopsies can be analyzed by nucleic acid hybridization to directly detect the presence of HPV DNA.

HPV 6/16 TaqMan PCR Kit, 100 reactions

  • Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
  • Specific Primer and Probe mix for the pathogen/virus/viroid of interest
  • Primer and Probe mix
  • Positive and negative control to confirm the integrity of the kit reagents

HPV 6/16 TaqMan PCR Probe/Primer Set and Controls, 100 reactions

  • Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
  • Nuclease-free water
  • Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix

For research use only and NOT intended for in vitro diagnostics.

Details

Supporting Data

Figure 1 / 5

Previous

Figure 1. HPV 6/16 TaqMan PCR Kit
Figure 1. HPV 6/16 TaqMan PCR Kit
Figure 2. HPV 6/16 TaqMan PCR Kit
Figure 3. HPV 6/16 TaqMan PCR Kit
Figure 4. HPV 6/16 TaqMan PCR Kit
Figure 5. HPV 6/16 TaqMan PCR Kit

Next

Click for expanded view

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.

ComponentTaqMan Probe
Cat. TM42050
(100 preps)
TaqMan
Probe/Primer
and Control Set
Cat. TM42010
(100 preps)
MDx TaqMan 2X PCR Master Mix2 x 700 µL
HPV 6/16 Primer & Probe Mix280 µL280 µL
HPV 6/16 Positive Control150 µL150 µL
Nuclease-Free Water (Negative Control)1.25 mL1.25 mL
Product Insert11

40×0.2ml Angle Rotor