E. coli O157:H7 is a rod-shaped, gram negative bacterium. It is an enterohemorrhagic strain of the common E. coli bacterium and infection by the O157:H7 strain is commonly associated with hemorrhagic colitis. E. coli O157:H7 is recognized by its somatic (cell wall) antigen (O157) and its flagella antigen (H7). In addition, E. coli O157:H7 is known to produce Shiga-like toxins, which cause severe symptoms. While most patients can recover from the infection, up to 15% of the patients may develop hemolytic uremic syndrome, a type of kidney failure that could be fatal. Infection of E. coli O157:H7 usually results from consumption of poorly prepared food including undercooked meat (particularly ground beef), untreated water or raw unpasteurized milk.
E.coli O157:H7 TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
E.coli O157:H7 TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
The IdPath™ COVID-19 Real-Time RT-PCR Kit is a real-time RT-PCR test intended for the detection of SARS-CoV-2 virus RNA which might be extracted from the respiratory tract specimens. The Kit provides reagents for multiplex real-time RT-PCR to detect SARS-CoV-2 by one-step reaction, specifically targeting the E (Envelope), RdRP (RNA-dependent RNA polymerase) and N (Nucleocapsid protein) gene for SARS-CoV-2 virus.
The Kit contains the RT enzyme mix and qPCR master mix for reverse transcription and real-time PCR of virus RNA. The COVID-19 Control (positive control) and ddWater (negative control) are used as indicators to avoid false negative/positive results across all experimental procedures. The Primers/probes Mix contains multiplex primers and TaqMan probes specific to the N, E/RdRP genes of SARS-CoV-2 and RNase P gene of human, detected by FAM, VIC and ROX channels, respectively.
For Research Use Only
Features
High Sensitivity:5×102 copies/ml (10 copies/rxn)
High Inclusivity : >99% of currently available complete virus genomes for SARS-CoV-2 including Omicron variant
High Accuracy : Clinical validation with 100% accuracy
High Stability : 37/25°C for 2 weeks ; 4°C for 24 weeks ; 10 times of freeze-thaw cycles
High Compatibility : Suitable for most laboratory qPCR machines
Operation Control : Including internal control for quality control of total process
Convenience : Multiplex (E/RdRP and N) detection by one-step reaction
Storage
Aliquot to avoid multiple freeze-thaw cycles
Protect fluorogenic probes from light
-20°C for 12 months
Document
The IdPath™ COVID-19 Real-Time RT-PCR Kit is a real-time RT-PCR test intended for the detection of SARS-CoV-2 virus RNA which might be extracted from the respiratory tract specimens. The Kit provides reagents for multiplex real-time RT-PCR to detect SARS-CoV-2 by one-step reaction, specifically targeting the E (Envelope), RdRP (RNA-dependent RNA polymerase) and N (Nucleocapsid protein) gene for SARS-CoV-2 virus.
The Kit contains the RT enzyme mix and qPCR master mix for reverse transcription and real-time PCR of virus RNA. The COVID-19 Control (positive control) and ddWater (negative control) are used as indicators to avoid false negative/positive results across all experimental procedures. The Primers/probes Mix contains multiplex primers and TaqMan probes specific to the N, E/RdRP genes of SARS-CoV-2 and RNase P gene of human, detected by FAM, VIC and ROX channels, respectively.
DBCO-C6-NHS ester is an amine-reactive compound, which can be used to modify an amine-containing molecule in organic media. This reagent isn’t soluble in aqueous media. The extended 6-carbon atom spacer arm improves solubility in commonly used organic solvents including dichloromethane, chloroform, THF, and ethyl acetate and it also improves derivatization efficiency and stability of conjugates. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
DBCO-C6-NHS ester is an amine-reactive compound, which can be used to modify an amine-containing molecule in organic media. This reagent isn’t soluble in aqueous media. The extended 6-carbon atom spacer arm improves solubility in commonly used organic solvents including dichloromethane, chloroform, THF, and ethyl acetate and it also improves derivatization efficiency and stability of conjugates. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.