
Description
Specifications
Clone | IHC067 |
Source | Mouse Monoclonal |
Positive Control | Tonsil |
Dilution Range | 1:200 |
Ki-67 is a nuclear, non-histone protein that is expressed only during active phases of the cell cycle (G1, S, G2 and M), but not in the resting phases (G0 and G1 early phase). Although the antigen has also been associated with ribosomal RNA transcription, it is strongly linked to cell proliferation and has thus been indicated as an effective marker in grading the proliferation rate of tumors, including those of the brain, breast, cervix, and prostate.
Clone | IHC067 |
Source | Mouse Monoclonal |
Positive Control | Tonsil |
Dilution Range | 1:200 |
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Specifications
Features | Specifications |
Recommended application | Plasmid maxi preparation |
Preservation conditions | Room temperature |
Stability | Up to 4 years |
Filter membrane | High quality glass fiber filter GF/B, 8 layers |
Membrane aperture | 1.0 μm |
Maximum binding yield of plasmid | 1 mg |
Maximum yield of alcohol mediated binding | 5 mg |
Plasmid yield | Up to 1mg |
Single liquid carrying capacity of column | 12 ml |
Minimum elution volume | 700 μl |
Withstand centrifugal force | 8000 rpm |
Centrifuge | Low speed centrifuge for 50ml centrifugetubes, >8000rpm, swing-out Rotor, or Fixed Angle Rotor |
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No. | Product Name | Package |
C13124 | HiPure DNA Maxi Column C (8 x GF/B)with two of 50ml High speedcentrifuge Tubes | 100/Bag |
Item No. | Product Name | Membrane type/number of layers | Collection tubes | Plasmid DNA binding capacity (Physical adsorption) | gDNA/RNA binding capacity (Alcohol-mediated adsorption) | Minimum Elution volume | Liquid volume capacity |
C13010 | HiPure DNA Nano Column | 2 layers GF/F | 2ml without cap | 5μg | 20μg | 10μl | 700μl |
C13011 | HiPure DNA Micro Column | 3 layers GF/F | 2ml without cap | 10μg | 50μg | 15μl | 700μl |
C13100 | HiPure DNA Mini Column I | 2 layers GF/B | 2ml without cap | 15μg | 100μg | 30μl | 700μl |
C13110 | HiPure DNA Mini Column II | 4 layers GF/B | 2ml without cap | 35μg | 200μg | 50μl | 800μl |
C13111 | HiPure RNA Mini Column | 3 layers GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13112 | HiPure Viral Mini Column | 3 layers GF/F | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13113 | HiPure CFDNA Mini Column | 3 layers GF/F,1 layer GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13120 | HiPure DNA Midi Column | 4 layers GF/B | 15ml Centrifuge tube | 125μg | 1mg | 500μl | 4ml |
C13121 | HiPure DNA Midi Column III | 8 layers GF/B | 15ml Centrifuge tube | 250μg | 1mg | 500μl | 4ml |
C13122 | HiPure DNA Maxi Column | 4 layers GF/B | 50ml Centrifuge tube | 500μg | 5mg | 1000μl | 20ml |
C13123 | HiPure DNA Maxi Column III | 8 layers GF/B | 50ml Centrifuge tube | 1mg | 5mg | 1000μl | 20ml |
C13124 | HiPure DNA Maxi Column C | 8 layers GF/B | 50ml high speed Centrifuge tube | 1mg | 5mg | 700μl | 12ml |
C13130 | HiPure DNA Plate | 2 layers GF/F | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
C13131 | HiPure gDNA Plate | 2 layers GF/B | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
TD4 Serofuge/Immunity centrifuge
Features:
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, laboratory and biochemistry.
2. Brushless motor, free maintenance, no powder pollution, quick in speed up and down.
3. The flexible axle driven system which drive the rotor directly, smooth in operation and small vibration.
4. Micro computer control system, digital display the RCF,time and speed.
5. Electric lid lock, compact design, super speed and imbalance protection.
TD4 Technical Data:
Max Speed | 4500rpm | Max RCF | 2260×g |
Max volume | 12×7ml | Power supply | AC 220V 50HZ 1A |
Timer | 0~99min | Noise | ≤55dBA |
Dimension(DxWxH) | 485×320×255mm | Net weight | 23 KG |
Speed accuracy | ±20rpm | Package | Carton box |
Matched Rotors for TD4:
Rotor Name | Max. Speed | Max. Volume | Max RCF(×g |
HLA rotor for Lymphocyte washing | 4500RPM | 12*2/1.5/0.5 | 2260*g |
SERO rotor for erythrocyte washing | 3000RPM | 12*7/5ml(10-13*65-100) | 1000*g |
Sample type purification kit guide
The 16S V2-V3 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the 16S V2-V3 amplicon libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XP Magnetic Beads (supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal swab, plasma/serum, tongue swab, gum swab, and others.
The 16S V2-V3 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the V2-V3 region of the DNA encoding 16S rRNA. The post-PCR reaction is then cleaned up using AMPure XP beads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XP beads. The libraries are then ready for quantification, pooling and sequencing.
Figure 1 / 3
Click for expanded view
Minimum amount of starting material: | 2.5 µL of DNA (5 ng/µL) |
Time to complete library preparation: | 4 hours |
Storage Conditions and Product Stability
Norgen’s 16S V2-V3 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components should remain stable for at least 1 year when stored at the specified storage conditions.
Step | Component | Cat. 70300 (24 preps) | Cat. 70310, 70320, 70330, 70340 (96 preps) |
---|---|---|---|
Amplicon PCR (PCR 1) | MGX Master Mix | 330 µL | 1,320 µL |
16S V2-V3 Primer Mix | 70 µL | 280 µL | |
Index PCR (PCR 2) | Indexing Master Mix | 660 µL | 2 x 1,320 µL |
N7xx Index Primer | 50 µL | 50 µL | |
S5xx Index Primer | 70 µL | 70 µL | |
PCR Clean-Up | Resuspension Buffer | 2 x 1,250 µL | 2 x 5,000 µL |
Nuclease-free water | 1,250 µL | 1 x 6,000 µL |
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map