Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
150 reactions
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit. Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Other Products
D3115 HiPure Tissue&Blood DNA Maxi Kit
Product Info
Document
Product Info
Introduction
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA (e.g., genomic, viral, mitochondrial) can be purified from whole blood, tissue and culture cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from 10ml blood and 1g tissue using Maxi column
Applications
PCR, southern bolt and virus detection, etc
Purification method
Maxi spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot, semen and other clinical samples
Sample amount
3-10ml
Elution volume
≥700μl
Time per run
≤90 minutes
Liquid carrying volume per column
4ml
Binding yield of column
5mg
Principle
This product is based on silica column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Pertinence – specially designed for isolating DNA from 3-10ml blood and related body fluids
Wide applicability – handle a variety of liquid samples
Proteinase K, RNase A should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
*Note:Leukocyte protocol can be used when large volume whole blood samples need to be processed. Whole blood was treated with red blood cell lysate, and white blood cells were obtained by centrifugation before extraction
Select the right purification kit to get impactful results:
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA (e.g., genomic, viral, mitochondrial) can be purified from whole blood, tissue and culture cells.
The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation up to 80µg endotoxin-free plasmid DNA from 5-15ml bacterial culture. Recommend for low copy vector, Thoroughly remove RNA
Applications
Cell transfection, animal injection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Low copy plasmid vector
Sample amount
5-15ml LB
Yield
10-70μg
Elution volume
≥75μl
Time per run
≤40 minutes
Liquid carrying volume per column
800μl
Binding yield of column
70μg
Principle
The HiPure Plasmid procedure is based on alkaline lysis of bacterial cells followed by adsorption of DNA onto silica in the presence of high salt. The unique silica membrane used in the kit completely replaces glass or silica slurries for plasmid DNA minipreps. The procedure consists of 3 basic steps: Preparation and clearing of a bacterial lysate by alkaline method,then transfer the supernatant to column to bind DNA. After washing proteins and other impurities, nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High purity – purified plasmid can be directly used in sequencing, enzyme digestion and PCR, etc.
Fast – silica gel column purification is much faster than ion exchange
High yield – up to 70μg plasmid can be binded in one column
Low endotoxin content – the obtained plasmid can be directly used in cell transfection and animal injection
Kit Contents
Contents
P115402
P115403
Purification Times
50 Preps
250 Preps
RNase A
5 mg
20 mg
Buffer P1
30 ml
140 ml
Buffer P2
30 ml
140 ml
Buffer LEN3
15 ml
70 ml
Buffer LN4
50 ml
250 ml
Buffer LN5
30 ml
140 ml
Buffer PW1
30 ml
140 ml
Buffer PW2
12 ml
50 ml
Elution Buffer
15 ml
30 ml
HiPure DNA Mini Columns III
50
250
2 ml Collection Tubes
50
250
Storage and Stability
The kit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve. After addition of RNase A,Buffer P1 is stable for 6 months when stored at 2–8°C.
The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
Our SNPsig® kits use our own proprietary genotyping method to enable the identification of SARS-CoV-2 variants of concern. These products can be used on any real-time PCR machine using familiar protocols, whilst resulting in exceptional genotyping data.
Positive control templates for wild-type and variants are supplied in every kit to make data interpretation simple.
Our SNPsig® technology provides an alternative to sequencing as well as S gene target failure (SGTF) that enables scientists to analyse and monitor these specific genomic mutations. Our kits can provide a pivotal role in screening for SARS-CoV-2 variants for the purpose of genomic surveillance and studies.
Document
For the detection of the SARS-CoV-2 (20H/501Y.V2 South Africa)
Rapid detection of specific detection profiles
High priming efficiency
Sensitive to < 100 copies of target
Positive copy number standard curve for quantification
Accurate controls to confirm findings
96 reactions, includes master mix