Human Enterovirus (HEV) TaqMan RT-PCR Detection Kits
Facebook
X
Pinterest
Email
Detail
Overview
Detection kits for HEV
CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
The Enteroviruses are a genus of the family Picornaviridae, and are a large and diverse group of small RNA viruses characterized by a ssRNA molecule of positive sense. To date, over 70 serotypes of Enterovirus have been isolated from man. The human enteroviruses include poliovirus, Coxsackie A and Coxsackie B viruses, enterocytopathic human orphan (ECHO) viruses and other enteroviruses. Enteroviruses infect millions of people worldwide each year, and the infection can result in a wide variety of symptoms depending on the serotype of the enterovirus. Symptoms of infection may include, but are not limited to, mild respiratory illness (common cold), hand, foot and mouth disease, Rubelliform rashes, acute hemorrhagic conjunctivitis, aseptic meningitis, myocarditis, and neonatal infections.
HEV TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
HEV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. TM39750 (100 preps)
Cat. TM39710 (100 preps)
MDx TaqMan 2X PCR Master Mix
2 x 700 μL
–
Enterovirus Primer & Probe Mix
280 μL
280 μL
Enterovirus Positive Control
150 μL
150 μL
Nuclease-Free Water (Negative Control)
1.25 mL
1.25 mL
Product Insert
1
1
Other Products
D3115 HiPure Tissue&Blood DNA Maxi Kit
Product Info
Document
Product Info
Introduction
Blood samples contain rich DNA, including mitochondrial DNA, genomic DNA, circulating DNA (mostly released into blood after tumor cell apoptosis) in white blood cells, as well as parasitic viral or microbial DNA. These DNA are important parameters in clinical testing or diagnosis, which are also valuable materials for medical research. There are three main issues with extracting DNA from blood samples:
1. The sample is highly infectious, posing great harm to operators and the environment.
2. The source of DNA is complex and aportion of the nucleic acid, such as viral DNA or free DNA, may be lost during the operation, leading to downstream detection failure;
3. Blood sample contains a large amount of impurities and inhibitory factors.
Currently there are many methods available for extracting DNA from whole blood samples, such as phenol chloroform extraction, salting out method, etc. However, these methods require pre-treatment of blood sample, which removes red blood cells and isolate white blood cells in the first step. Due to the requirement that it cannot inactivate or kill pathogens during the process of removing red blood cells, the waste liquid (red blood cell lysate) and consumables may be contaminated by pathogens and become infectious, posing a danger to the entire laboratory environment and operators. In addition, during the process of removing red blood cells, useful nucleic acid information such as viruses, microorganisms, or circulating DNA is also lost, leading to experiment or detection failures.
The HiPure Blood DNA Kits series provided by Magen Company uses silica gel column purification technology, which can directly lyse whole blood samples without the need for white blood cell separation. Whole blood samples are directly mixed with lysates and proteases, resulting in the inactivation of pathogens, greatly reducing the infectivity, environmental pollution, and the chance of operators being infected. Due to the direct lysis and digestion of samples, except lymphocyte DNA, other circulating DNA as well as DNA from viruses and microorganisms, can also be recovered.
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA (e.g., genomic, viral, mitochondrial) can be purified from whole blood, tissue and culture cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from 10ml blood and 1g tissue using Maxi column
Applications
PCR, southern bolt and virus detection, etc
Purification method
Maxi spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Tissue, cell, blood, saliva, swab, blood spot, semen and other clinical samples
Sample amount
3-10ml
Elution volume
≥700μl
Time per run
≤90 minutes
Liquid carrying volume per column
4ml
Binding yield of column
5mg
Principle
This product is based on silica column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
Fast – without separation of leukocytes, organic extraction or ethanol precipitation
Simple – all nucleic acids can be obtained by direct digestion
Pertinence – specially designed for isolating DNA from 3-10ml blood and related body fluids
Wide applicability – handle a variety of liquid samples
Proteinase K, RNase A should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
*Note:Leukocyte protocol can be used when large volume whole blood samples need to be processed. Whole blood was treated with red blood cell lysate, and white blood cells were obtained by centrifugation before extraction
Document
Blood samples contain rich DNA, including mitochondrial DNA, genomic DNA, circulating DNA (mostly released into blood after tumor cell apoptosis) in white blood cells, as well as parasitic viral or microbial DNA. These DNA are important parameters in clinical testing or diagnosis, which are also valuable materials for medical research. There are three main issues with extracting DNA from blood samples:
TD4N Table Top 5000rpm Low Speed Laboratory Centrifuge
Product Info
Document
Product Info
TD4N Table Top 5000rpm Low Speed Laboratory Centrifuge
TD4N Features:
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, blood center, laboratory and biochemistry.
2. Brushelss motor, free maintenance, no powder pollution, quick in speed up and down.
3. The flexible axle driven system which drive the rotor directly, smooth in operation and small vibration.
4. There are many rotors for your choice, suitable for different specifications meet customers’ different requirements of separation.
5. Micro-computer control system, digital display the RCF, time and speed.
6. Electric lid lock, compact design, super speed and imbalance protection.
TD4N Technical Parameter:
Max. Speed
5000rpm
Speed Accuracy
±20rpm
Max. Volume
6x100ml
Power Supply
AC110V/220V 50HZ/60HZ
Max. RCF
3460xg
Noise
≤55dBA
Timer
0~99min
Net Weight
18Kg
Dimension
540x370x280mm
Certifications
CE, ISO & Calibration report are available.
Warranty
1 Year
Matched Rotors for TD4N:
Order No.
Rotor Type
Max.Speed(rpm)
Max.Volume(ml)
Max.RCF(xg)
4N-1
Swing Rotor
5000
6x10ml
3460
4N-2
Angle Rotor
4000
30×7/5ml
2250
4N-3
Angle Rotor
4000
18×15/10ml
2250
4N-4
Angle Rotor
4000
24x10ml
2200
4N-5
Angle Rotor
4000
12×15/7/5ml
2150
4N-6
Angle Rotor
4000
12x20ml
2200
4N-7
Angle Rotor
5000
6x15ml
2540
4N-8
Angle Rotor
5000
12x15ml
3080
4N-9
Angle Rotor
5000
4x50ml
2520
4N-10
Angle Rotor
5000
6x50ml
2850
4N-11
Angle Rotor
5000
4x100ml
2630
4N-12
Angle Rotor
5000
6x100ml
3130
Document
TD4N is a table top centrifuge widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, blood center, laboratory and biochemistry.
t-Boc-N-amido-PEG4-Amide-Tri-(propargyl-PEG10-ethoxymethyl)-methane is a branched crosslinker molecule with three terminal propargyl groups and a t-Boc protected amide group. The propargyl groups can react with azide-bearing compounds or biomolecules via copper catalyzed azide-alkyne Click Chemistry to yield a stable triazole linkage. The protected amine can be deprotected under acidic conditions. Reagent grade, for research use only.
Document
t-Boc-N-amido-PEG4-Amide-Tri-(propargyl-PEG10-ethoxymethyl)-methane is a branched crosslinker molecule with three terminal propargyl groups and a t-Boc protected amide group. The propargyl groups can react with azide-bearing compounds or biomolecules via copper catalyzed azide-alkyne Click Chemistry to yield a stable triazole linkage. The protected amine can be deprotected under acidic conditions. Reagent grade, for research use only.