Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective.
Detail
Overview
Heat sealing offers a 100% effective method of plate sealing, for complete seal integrity, as well as being quick and cost effective.
Our Individual Access Peel Heat Seal is a laminate seal compatible with polypropylene plates, featuring 96 individual foil seal spots or 12 strips of individual spots on a removable backing.
These seals result in individually sealed tubes/strips, and they can be removed from polypropylene plates by peeling, even with a plate which has been removed directly from -80°C storage.
Individual Access Peel Heat Seal forms a complete seal to a plate enabling very low temperature uses, including very low temperature storage, and high temperature uses, such as PCR (when used with a pressurized heated lid).
The seal demonstrates moderate solvent resistance and can be utilized for short term compound storage at room temperature.
This seal is available as sheets, for use with manual and semi-automated sealers, such as our Semi-Automated Sheet Heat Sealer (using the 59-2005 Individual Access adapter).
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature:at room temperature and constant temperature(generally 39℃~42℃),reverse transcriptaseuses specific primers and template RNA tosynthesize cDNA strands,and binds the auxiliary protein and single strand with the help of the protein, the recombinase and the primer form a complex; perform a homology search and bind the target homology domain, at this time a D-loop region is formed at the homology positionand strand exchange begins; accompanied by the recombinase from the complex upon dissociation,the polymerase also bindsto the 3′ end of the primer,initiating chainextension.It is suitable for laboratory-level RNA amplification and RNA amplification for other detection purposes.
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
3/ The reaction can be operated by metal bath and water bath pot without purchasing expensive PCR apparatus.
Technical Parameters:
Parameters
Details
Product Name
RNA Isothermal Amplification Kit Basic
Manufacturer
Amp-future
Storage Temperature
-20°C
Kit Components
Enzymes, Buffers ,Reagents
Packaging
48 Tests/box
Detection Limit
500-1000copies/µL
Shipping
ICE
Test Time
5-20mins
Isothermal nucleic acid Applications
Suitable for RNA isothermal rapid amplification kit(Basic type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
RNA basic kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.
The α-D-Glucuronidase test kit is a simple, reliable and accurate method for the measurement and analysis of α-D-glucuronidase in various enzyme preparations. The kit contains a pure aldotriouronic acid substrate and an α-D-glucuronidase (GH67) control enzyme.
New, improved substrate.
This kit contains highly purified, borohydride reduced aldotriouronic acid with a terminal α-D-glucuronic acid substitution, which is an excellent substrate for α-D-glucuronidases from GH67. This substrate can be also used for the measurement of α-D-glucuronidases from GH115, however the rate of hydrolysis compared to GH67 is reduced. Previously this kit contained a mixture of borohydride reduced aldouronic acids (tri:tetra:penta).
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The α-D-Glucuronidase test kit is a simple, reliable and accurate method for the measurement and analysis of α-D-glucuronidase in various enzyme preparations. The kit contains a pure aldotriouronic acid substrate and an α-D-glucuronidase (GH67) control enzyme.
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.