This product is suitable for extracting total viral nucleic acid from cell-free/low-content cell biological samples such as body fluids, serums, plasma, soaking solutions, tissue homogenate supernatant, and culture supernatant. The Purified DNA/RNA is used for RT-PCR and PCR detection.
Detail
Introduction
This product is suitable for extracting total viral nucleic acid from cell-free/low-content cell biological samples such as body fluids, serums, plasma, soaking solutions, tissue homogenate supernatant, and culture supernatant. The Purified DNA/RNA is used for RT-PCR and PCR detection.
Details
Specifications
Features
Specifications
Main Functions
IVD5412 precast kit for MagMix 32, smart 32
Applications
RT-PCR,PCR,NGS
Products
Viral DNA / RNA, body cell DNA / RNA
Purification method
Polydisperse magnetic beads
Purification technology
Magnetic beads technolog
Process method
Manual or automatic
Sample type
Sample amount
200μl
Adaptive instrument
Nucleic acid extractor, pipetting workstation
Principle
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Protease. DNA/RNA is released into the lysate. After adding magnetic particles and binding solution, DNA/RNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA/RNA was eluted by Nuclease Free Water.
This kit is shipped and stored at room temperature and is valid for 12 months.
Other Products
Fecal DNA Collection & Preservation Mini Tubes
Product Info
Document
Product Info
Overview
No need to immediately process samples
Includes pre-loaded beads for effective sample homogenization by bead beating (tubes are fully compatible with commercially available bead beating systems)
DNA preservation at room temperature over 2 years
Ship fecal samples at room temperature safely
Compatible with most DNA isolation methods
Norgen’s Fecal DNA Collection & Preservation Mini Tubes are designed for the rapid preservation of DNA from fresh fecal specimens. These tubes contain Norgen’s Fecal DNA Preservative in a liquid format. Moreover, each collection tube is preloaded with beads for effective sample homogenization in any commercially available bead beater equipment (e.g. MP Biomedicals’ FastPrep®-24). The user simply collects fecal samples into the tubes and mixes by shaking or vortexing until the feces is mixed well with preservative. The preservative prevents the growth of Gram-negative and Gram-positive bacteria and fungi, and also inactivates viruses allowing the resulting non-infectious samples to be handled and shipped safely. In addition, the preservative eliminates the need to immediately process or freeze samples and allows the samples to be shipped to centralized testing facilities at ambient temperatures. The components of the preservative allow the DNA in the samples to be preserved at room temperature for over 2 years.
This kit is highly suited to collection and preservation of fecal material from mouse, hamster, chinchilla, rabbit and more for microbiome studies and other applications.
DNA Isolation from Preservative
Fecal samples collected and preserved in Norgen’s Fecal DNA Collection and Preservation Mini Tubes are compatible with most fecal DNA isolation methods. Samples stored in the tubes have been used successfully with all of Norgen Biotek’s stool-based DNA isolation kits (please refer to Related Products table) and reagents.
Free Download
Extracting Biological Insights from Stool
Tips and tricks for isolating high yield and quality DNA, RNA, miRNA and EV’s from fecal samplesDownload for Free
Storage Conditions and Product Stability All tubes should be kept tightly sealed and stored at room temperature (15 – 25°C) for up to 2 years without any reduction in performance.
Kit Components
Cat. 27650
Fecal DNA Collection & Preservation Mini Tubes (containing liquid preservative and beads)
NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms)
Product Info
Document
Product Info
The NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality NGS libraries with low input DNA amount from 1 ng to 400 ng. The kit allows scientist to study samples with limited DNA such as tumor samples, patient samples, and other specially collected samples (FACS sorting etc.). The kit has high library conversion efficiency with as little as 1 ng DNA input. The fast and simple 1.5-hour protocol makes libraries with even coverage and low GC-bias based our unique chemistry for DNA end-polishing and ligation.
The kit needs double strand DNA fragments (blunt and/or sticky) as input DNA for NGS library preparation, and is compatible with DNA fragments generated from both enzymatic approach (for example, BioDynami DNA fragmentation enzymes, Cat.# 40061 and Cat.# 40062) and mechanical approaches such as sonication and nebulization etc.
NGS Low Input DNA Library Prep Kit Workflow
Three index types are available for the NGS Low Input DNA Library Prep Kit of illumina platform:
Non-index (Cat.# 30022): Libraries do not have index.
Index (Cat.# 30024): Each of our index primers contains a unique barcode sequence with 6 bases that can be used to identify the low input DNA libraries. Library multiplexing up to 48 samples is possible. Index information can be downloaded here.
Unique dual index (Cat.# 30025): Library multiplexing up to 96 low input DNA libraries is possible with unique dual indexes with our Four-Base Difference Index System. The system allows us to make indexes for the libraries that have at least 4 bases different from each other in the 8-base barcode length. Our unique dual index primers can reduce sequencing errors such as de-multiplexing errors, amplification errors, mis-assignment of reads, index cross-contamination, and also index hopping. The kit includes 96 pre-mixed unique pairs of index primers. Index information can be downloaded here.
Indexes are available for the MGI platform kits (Cat.# 34024).
Kit advantages:
Fast protocol
The hands-on time is only 10 minutes
The total protocol time is around 1.5 hours
Simple procedure
Ready-to-use master mix makes it simple for reaction setup
Less reaction components
Less magnetic beads required for cleanup steps: Save the cost more than 50%
Low input DNA amount: Starts from 1 ng of DNA
Comparison of library conversion efficiency under the same NGS library preparation condition. Input DNA amounts are 1 ng and 10 ng, respectively. DNA was mechanical sheared with Covaris before library prep. BioDynami kit: NGS Low Input DNA Library Prep Kit (Cat. #30022).
Comparison of library yield under the same NGS library prep condition. Input DNA amounts are 1 ng, 10 ng, and 100 ng. DNA was mechanical sheared with Covaris before library prep. BioDynami kit (Cat. #30022). PCR cycle numbers were indicated.
Document
The NGS Low Input DNA Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality NGS libraries with low input DNA amount from 1 ng to 400 ng. The kit allows scientist to study samples with limited DNA such as tumor samples, patient samples, and other specially collected samples (FACS sorting etc.). The kit has high library conversion efficiency with as little as 1 ng DNA input. The fast and simple 1.5-hour protocol makes libraries with even coverage and low GC-bias based our unique chemistry for DNA end-polishing and ligation.
Blood Urea Nitrogen Enzymatic Kit is a microplate-based colorimetric assay for the determination of urea in serum samples produced from blood. Blood urea nitrogen (BUN) is an important marker for normal kidney and liver function. Elevation of BUN levels is often an indication of intestinal and kidney obstruction and cardiac failure. Decreased BUN levels are often associated with kidney and liver damage. BUN is also a very useful tool for preclinical investigation of experimental drug formulations and BUN levels are commonly used to monitor and attenuate the toxic effects of experimental drug formulations in rodents.
Blood Urea Nitrogen Enzymatic Kit uses an enzyme-based assay to determine urea in liquid samples such as serum. The test is based on a highly proven method for urea determination. The Blood Urea Nitrogen Enzymatic Kit contains sufficient materials to test 42 samples in duplicate. The assay utilizes urease, a metabolic enzyme, to specifically detect urea in serum. The Blood Urea Nitrogen Enzymatic Kit provides rapid, accurate, proven results even in complex liquid mixtures. The limit of detection for the test is 8 ppm urea for serum. The linear range of the assay is 8 – 200 ppm analyte.
Document
96 determinations
Rapid and simple method
Minimal sample prep
Highly accurate and reproducible