The L-Lactic Acid (L-Lactate) Assay Kit is used for the specific measurement and analysis of L-lactic acid (L-lactate) in beverages, meat, dairy and food products.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 1 year under recommended storage conditions
Analyte:
L-Lactic Acid
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
0.3 to 30 µg of L-lactic acid per assay
Limit of Detection:
0.21 mg/L
Reaction Time (min):
~ 10 min
Application examples:
Wine, beer, soft drinks, milk, dairy products (e.g. cream, milk / whey powder, cheese, condensed milk and yogurt), foods containing milk (e.g. dietetic foods, bakery products, baby food, chocolate, sweets and ice-cream), egg, egg products (e.g. egg powder), baking additives, vinegar, fruit and vegetables, processed fruit and vegetables (e.g. tomatoes), meat products, food additives, feed, paper (and cardboard), cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by DIN, GOST, IDF, EEC, EN, ISO, OIV, IFU, AIJN and MEBAK
The L-Lactic Acid (L-Lactate) Assay Kit is used for the specific measurement and analysis of L-lactic acid (L-lactate) in beverages, meat, dairy and food products.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.
Very competitive price (cost per test)
All reagents stable for > 2 years after preparation
Rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Other Products
R4171 HiPure Viral RNA Kit
Product Info
Document
Product Info
Introduction
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.
Details
Specifications
Features
Specifications
Main Functions
Extract viral RNA from 140μl cell-free samples
Applications
RT-PCR, Northern hybridization, and various virus detection
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Cell-free body fluid or culture medium
Sample amount
140μl
Elution volume
≥15μ
Time per run
≤25 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such as guanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein and other impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
The sample is homogenized and lysed in the lysate, and RNA is released into the lysate. The high concentration of guanidine isothiocyanate contained in the lysate denatured and inactivated endogenous or exogenous RNase, while RNA is protected from degradation. The lysate is centrifuged to remove insoluble impurities. After adding ethanol to adjust the binding conditions, it is transferred to the column for filtration. RNA is adsorbed on the membrane of the column, while protein is removed without adsorption. The column is washed with buffer VHB to remove protein and other impurities, washed with buffer RW2 to remove salt. Finally the RNA is eluted by RNase free water. The eluted RNA can be directly used in RT-PCR, Northern blot, poly-A purification, in vitro translation, etc.
Advantages
Fast – several samples can be extracted in 20 minutes by column method
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
High yield – carrier RNA contained in the product maximize the recovery of trace nucleic acid
Kit Contents
Contents
R417102
R417103
Purification Times
50 Preps
250 Preps
HiPure Viral Micro Columns
50
250
2ml Collection Tubes
100
500
Buffer VRL
50 ml
200 ml
Carrier RNA
310 µg
3 x 310 µg
Buffer VHB*
13 ml
110 ml
Buffer RW2*
20 ml
2 x 50 ml
Nuclease Free Water
10 ml
30 ml
Storage and Stability
Carrier RNA should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under theseconditions
Document
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.
Permagen’s 15 mL Centrifuge Tube Magnetic rack is designed for magnetic bead separations from up to six, 15 mL Centrifuge tubes
Accommodates any common 15 mL Centrifuge Tubes
Beads will be pulled to back wall allowing easy aspiration and tip tracking down the front wall of the tubes without disturbing bead pellet
Features include solid aluminum alloy design with hard coat finish for years of trouble-free use, rubber feet to help prevent slipping on work bench, less tippy than common plastic products, and fast separations using any magnetic beads