1000 µL filtered pipette tips for the Opentrons Flex, provided sterile in racks or blister packs (refills). Tips are clear, non-conducting polypropylene tips, free of human DNA, PCR inhibitors, RNase/DNase, pyrogens, and endotoxins. Opentrons Flex Tips and Racks are autoclavable.
Detail
1000 µL filtered pipette tips for the Opentrons Flex, provided sterile in racks or blister packs (refills). Tips are clear, non-conducting polypropylene tips, free of human DNA, PCR inhibitors, RNase/DNase, pyrogens, and endotoxins. Opentrons Flex Tips and Racks are autoclavable.
Other Products
Adenovirus Purification Kit
Product Info
Document
Product Info
Overview
Adenovirus Purification from any input – cell fraction or media fraction
Rapid purification within 2 to 4.5 hours
No specialized equipment needed (ultracentrifuge not required)
Purify adenovirus cell culture supernatant from 1 mL to 33.5 mL input per prep
Purify adenovirus cell pellet from 1 mL of input per prep
Up to 25X sample concentration
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Adenoviral vectors are useful tools for both in vitro and in vivo gene transfer, and oncolytic viruses based on adenovirus are highly promising for cancer treatment. Norgen’s Adenovirus Purification Kit provides a fast and simple procedure for concentrating and purifying adenoviral vectors from cell lysate and cell culture media. Purification is based on spin column chromatography using Norgen’s proprietary resin as an ion exchanger. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. Adenoviral vectors purified in this manner are highly active for use in transduction experiments.
Norgen’s Adenovirus Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit.
At least 3×1011 adenovirus particles as determined by qPCR At least 3×108 transducing units as determined by transduction assay
Input type
Cells, media
Input volume (Supernatant)
1 – 33.5 mL SN per prep (500 mL SN in total)
Input Volume (Cell pellet)
1 mL cell pellet per prep (15 mL in total)
Minimum elution volume
1.3 mL per prep
Time to complete purification
2.5 to 4.5 hours with 1 hour hands on time
In vivo transduction
Yes
Storage Conditions and Product Stability
HL-SAN Nuclease should be stored at -20°C upon arrival. Elution Buffer P should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
[DM5100] ExcelBand™ Super Range DNA Ladder (50 bp-25 kb), 500 μl
Product Info
Document
Product Info
Description
The DM5100 ExcelBand™ Super Range DNA Ladder is a ready-to-use DNA ladder, which is pre-mixed with loading dye for direct gel loading. The DNA Ladder DM5100 is composed of 26 individual DNA fragments: 25k, 10k, 8k, 6k, 5k, 4k, 3k, 2.5k, 2k, 1.5k, 1.2k, 1k, 900, 800, 700, 600, 500, 450, 400, 350, 300, 250, 200, 150, 100 and 50 base pairs derived from a mixture of PCR products and specifically digested plasmid DNA. This product contains four enhanced bands (3k, 1.2k, 500 and 200 bp) for easier reference. In addition, three tracking dyes, Xylene cyanol FF, Bromophenol blue and Orange G which mimic the migration of 4,000 bp, 500 bp and 50 bp dsDNA during electrophoresis are added for real time monitoring.
Features
Sharp bands
Quick reference— enhanced bands
Ready-to-use— premixed with loading dye for direct loading
Stable— room temperature storage over 6 months
Source
Phenol extracted PCR products and dsDNA digested with specific restriction enzymes, equilibrated in 10 mM Tris-HCl (pH 8.0) and 10 mM EDTA.
Range
50 ~ 25,000 bp
Concentration
88.7 µg/ 500 µl
Recommended loading volume
5 µl/ well
Storage
Room temperature for 6 months 4°C for 12 months -20°C for 36 months