Opentrons Thermocycler GEN2 Seals are adhesive-backed Ethylene Propylene Diene Monomer (EPDM) seals designed for use with the fully-automated Thermocycler Module GEN2. They come in a package of 10 seals. These seals need to be applied to the hood of the Thermocycler and can be reused up to 20 times. Opentrons Thermocycler GEN2 Seals need to be sterilized before each use.
Note, if you have a Thermocycler Module GEN1, please use the Thermocycler GEN1 Seals.
Detail
Opentrons Thermocycler GEN2 Seals are adhesive-backed Ethylene Propylene Diene Monomer (EPDM) seals designed for use with the fully-automated Thermocycler Module GEN2. They come in a package of 10 seals. These seals need to be applied to the hood of the Thermocycler and can be reused up to 20 times. Opentrons Thermocycler GEN2 Seals need to be sterilized before each use.
This product provides fast and easy method for purification of high purity DNA from bone samples. The obtained DNA can be directly used for PCR and STR detection down stream application.
Details
Kit Contents
Contents
D312402
D312403
Purification Times
50
250
HiPure DNA Mini Columns I
50
250
2ml Collection Tubes
50
250
Buffer BGL
40 ml
180 ml
Buffer GXP
30 ml
150 ml
Buffer GW1*
13 ml
53 ml
Buffer GW2*
20 ml
2 x 50 ml
DTT Powder
235 mg
2 x 235 mg
Proteinase K
48 mg
240 mg
Protease Dissolve Buffer
5 ml
15 ml
Elution Buffer
15 ml
60 ml
Storage and Stability
This product can be stored at room temperature (15~25°C) for 18 months. Proteinase K/DTT dry powder can be transported and stored at room temperature. For long-term storage (>6 months), it is recommended to store at -20~8°C. Dissolved Proteinase K should be stored at -20~8°C. The dissolved DTT should be stored at -20°C.
Document
This product provides fast and easy method for purification of high purity DNA from bone samples. The obtained DNA can be directly used for PCR and STR detection down stream application.
This test discovers hop resistance genes in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 cfu/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.
Labelled specific primers are used to amplify specific DNA fragments. In addition to the target gene, a control gene, which is also present in the PCR mixes, is amplified in order to make sure that the PCR process works properly.
The resulting PCR products carry the labels of the incorporated primers.
In a second part of the test, the created PCR products are detected by a lateral flow Test Strip. A “molecular sandwich” is formed and becomes visible as a line on the test Strip.
Brief Instructions
The PCR reagents and the samples are prepared.
After the addition of the sample to the PCR reagents, the PCR is started.
The resulting PCR products are detected by a simple lateral flow test Strip
Name of Product
Hop Resistance Gene-Screen
Catalog Number
MGScHOR 1
Short Info
This test discovers hop resistance genes in a timely and precise manner
Method/Platform
PCR
Range/Assay Sensivity
10^4 – 10^5 cfu/mL
Test Principle
The technological basis for the GenLine tests is the polymerase chain reaction (PCR) combined with lateral flow Tests.
MagPure A4 XP utilizes Magen’s solid-phase paramagnetic bead technology for high-throughput purification of PCR amplicons. AmPure utilizes an optimized buffer to selectively bind PCR amplicons 100bp and larger to paramagnetic beads. Excess primes, nucleotides, salts and enzymes can be removed using a simple washing procedure. The resulting purified PCR product is essentially free of contaminants.
Details
Specifications
Features
Specifications
Main Functions
Selectively recover DNA from PCR products and enzymatic reaction solution (Replace Beckmen or agencourt AmPure XP)
Applications
NGS, DNA library
Purification technology
Magnetic beads technology
Process method
Manual (centrifugation or vacuum)
Sample type
DNA products, restriction endonuclease systems, or other enzymatic reaction solutions
Sample amount
Appropriate
Recovery
80%
Operation time
≤50 minutes
Principle
This product is based on the purification method of high binding magnetic particles. PCR amplicons mix with MagPure A3, 100bp and larger DNA binds to magnetic beads. Excess primes, nucleotides, salts and enzymes can be removed using a simple washing procedure and finally DNA was eluted by Elution Buffer or Water.
Advantages
High recovery – up to 80%
High throughput – using magnetic beads purification technology
Kit Contents
Contents
BP-5
BP-50
BP-500
MagPure A4 XP
5 ml
50 ml
500 ml
Storage and Stability
MagPure A4 XP should be stored at 2-8°C upon arrival and is stable up to 18 months under the condition. However, short-term storage (up to 4 weeks) at room temperature (15-25°C) does not affect its performance. — Shake the reagent well before use. It should appear homogenous and consistent in color.
DO NOT FREEZE.
Document
MagPure A4 XP utilizes Magen’s solid-phase paramagnetic bead technology for high-throughput purification of PCR amplicons. AmPure utilizes an optimized buffer to selectively bind PCR amplicons 100bp and larger to paramagnetic beads. Excess primes, nucleotides, salts and enzymes can be removed using a simple washing procedure. The resulting purified PCR product is essentially free of contaminants.