Compatible with most DNA and RNA isolation methods
Norgen’s Total Nucleic Acid Preservation Tubes Dx are designed for ambient preservation and transport of total nucleic acids (DNA and RNA) from samples collected using a swab. The Total Nucleic Acid Preservation Tubes contain Norgen’s Total Nucleic Acid Preservative in a liquid format. The user simply collects the specimen using a sterile nylon flocked swab (not provided), and then transfers the swab into the Total Nucleic Acid Preservative. The Preservative prevents the growth of Gram-negative and Gram- positive bacteria and fungi, and also inactivates viruses allowing the resulting non-infectious samples to be handled and shipped safely. In addition, the Total Nucleic Acid Preservative eliminates the need to immediately process or freeze samples and allows the samples to be shipped to centralized testing facilities at ambient temperatures. The components of the preservative allow DNA samples to be stored at room temperature for over 4 months and RNA samples to be stored at room temperature for over 2 months. This kit is ideal for collecting and preserving nasal and oral swab samples for in vitro diagnostic use for medical purposes. This kit can be used to preserve viral RNA, including SARs-CoV-2 RNA for detection of COVID-19.
Norgen’s Total Nucleic Acid Preservation Tubes Dx are intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques.
Norgen’s Total Nucleic Acid Preservation Tubes Dx do not provide a diagnostic result. It is the sole responsibility of the user to use and validate these devices in conjunction with a downstream in vitro diagnostic assay.
Shelf Life and HandlingThe tubes should be kept tightly sealed and stored at room temperature for up to 1 year without any reduction in performance (The collection due date is written on the device label and the kit box label).Once collected, RNA is stable for up to 2 months and DNA is stable for up to 4 months when the tubes are kept tightly sealed and stored at room temperature.
Kit Components
Cat. Dx69200
Total Nucleic Acid Preservation Tubes Dx
50
Product Insert
1
Other Products
ProteoSpin™ Urine Protein Concentration Kits
Product Info
Document
Product Info
Overview
Simultaneous concentration, desalting and buffer exchange of total urinary proteins
No molecular weight cutoff allows for isolation of all sizes of proteins and peptides
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
These kits concentrate urine proteins while simultaneously removing salts, urea, and other urine contaminants. There is no molecular weight cut-off and therefore the columns capture total urinary proteins and peptides of all sizes making them ideal for biomarker discovery work, differential expression of proteins in various diseases, or other diagnostic research. The columns are convenient, rapid and easy to use and thus offer significant time savings over classic dialysis protocols. The resulting high-quality protein sample is concentrated and free from the original sample salts, thus preparing the sample conveniently for downstream proteomic applications including SDS-PAGE, 2D Gels, MALDI-TOF, LC/MS, LC/MS/MS, whole protein mass spectrometry, western blotting, protein microarrays, and more.
ProteoSpin™ Urine Protein Concentration Micro Kit
Each spin column is able to concentrate and desalt up to 200 μg of urine proteins. Twelve samples can be processed in 20 minutes.
ProteoSpin™ Urine Protein Concentration Midi Kit
The ProteoSpin™ Urine Protein Concentration Midi Kit provides a fast and simple procedure for concentrating dilute solutions of urine proteins from 1 to 5 mL inputs of urine. Each mini spin column is able to concentrate and desalt up to 3 mg of urine proteins in 30 minutes.
ProteoSpin™ Urine Protein Concentration Maxi Kit
The ProteoSpin™ Urine Protein Concentration Maxi Kit provides a fast and simple procedure for concentrating dilute solutions of urine proteins from 2 to 20 mL inputs of urine. Each maxi spin column is able to concentrate and desalt up to 4 mg of urine proteins in 45 minutes.
*Yield will depend on the health status of the donor.
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. Once opened, the solution should be stored at 4°C. This kit is stable for 2 years after the date of shipment.
Component
Cat. 17400 (25 preps)
Cat. 52300 (10 preps)
Cat. 21600 (4 preps)
Wash Solution C
60 mL
60 mL
130 mL
Binding Buffer A
4 mL
4 mL
8 mL
Elution Buffer C
8 mL
30 mL
30 mL
Protein Neutralizer
4 mL
4 mL
4 mL
Micro Spin Columns
25
–
–
Midi Spin Columns (assembled with collection tubes)
–
10
–
Maxi Spin Columns (assembled with collection tubes)
The D-Glucosamine test kit is a high purity reagent for the measurement and analysis of D-glucosamine in neutraceutical/food products. This kit can also be used to measure N-Acetyl-D-Glucosamine and D-Glucosamine sulphate.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
All reagents stable for > 2 years after preparation
All enzymes supplied as stable suspensions
Very rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The D-Glucosamine test kit is a high purity reagent for the measurement and analysis of D-glucosamine in neutraceutical/food products. This kit can also be used to measure N-Acetyl-D-Glucosamine and D-Glucosamine sulphate.
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.