West Nile Virus (WNV) TaqMan RT-PCR Detection Kits
Facebook
X
Pinterest
Email
Detail
Overview
Detection kits for WNV
CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
West Nile Virus (WNV) belongs to the RNA virus family of Flaviviridae. It is known to spread primarily through arthropod vectors such as mosquitoes. The virus infects mainly birds but is also reported to infect humans as well as pets such as cats and dogs. In humans, the majority of the infections caused by WNV are asymptomatic. However, some individuals (the majority of the confirmed cases) could enter a second, febrile stage with flu-like symptoms – commonly known as West Nile Fever. In a more serious stage, the disease becomes neuroinvasive, causing meningitis or encephalitis. Such severe conditions could lead to mortality. As the symptoms of WNV are very similar to other common diseases but can be fatal at a severe stage, it is important to distinguish the virus early in the diagnosis, particularly at the molecular level.
WNV TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
WNV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. TM44250 (100 preps)
Cat. TM44210 (100 preps)
MDx TaqMan 2X PCR Master Mix
2 x 700 μL
–
WNV Primer & Probe Mix
280 μL
280 μL
WNV Positive Control
150 μL
150 μL
Nuclease-Free Water (Negative Control)
1.25 mL
1.25 mL
Product Insert
1
1
Other Products
Pilot-scale Freeze Dryer/ Lyphilizer
Product Info
Document
Product Info
Character
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Q-PAGE™ TGN (Tris-Glycine Novel) Precast Gels are ready-to-use acrylamide gels for SDS-PAGE running in Tris-Glycine buffer system. With unique formula, Q-PAGE™ TGN Precast Gels perform enhanced speed, better separation, and longer shelf life as compared with conventional Laemmli Tris-HCl gels. The protein migration patterns in Q-PAGE™ TGN series, however, are similar with typical Laemmli Tris-HCl gels, and thus Q-PAGE™ TGN Precast Gels are compatible to traditional SDS-PAGE and subsequent analyses.
Q-PAGE™ TGN Precast Gels are available in gradient (4 to 15%) and fixed (10%) concentrations of polyacrylamide in 12- and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP4XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP5XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Key Features
User-friendly gel cassette:
Numbered and framed wells for sample loading
Labeled warning sign and green tape as reminder
Enhanced gel performance:
Enhanced gel electrophoresis speed
Better band separation
Stable for shipping at ambient temperature
Easy compatibility:
Available as homogeneous and adjusted gradient gels for a wide range of protein separation.
Compatible with most popular protein electrophoresis systems
Storage and stability
Store Q-PAGE™ Precast Gels at 4°C for periods up to 12 months.
Do not freeze Q-PAGE™ Precast Gels. Remove tape and comb before electrophoresis.
Keep Q-PAGE™ Precast Gels flat during storage.
Document
Q-PAGE™ TGN (Tris-Glycine Novel) Precast Gels are ready-to-use acrylamide gels for SDS-PAGE running in Tris-Glycine buffer system. With unique formula, Q-PAGE™ TGN Precast Gels perform enhanced speed, better separation, and longer shelf life as compared with conventional Laemmli Tris-HCl gels. The protein migration patterns in Q-PAGE™ TGN series, however, are similar with typical Laemmli Tris-HCl gels, and thus Q-PAGE™ TGN Precast Gels are compatible to traditional SDS-PAGE and subsequent analyses.
Q-PAGE™ TGN Precast Gels are available in gradient (4 to 15%) and fixed (10%) concentrations of polyacrylamide in 12- and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP4XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP5XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Details
Specifications
Features
Specifications
Recommended application
gDNA extraction, RNA extraction, DNA/RNA clean up
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/B, 2 layers
Membrane aperture
1.0μm
Maximum binding yield of plasmid
15 μg
Maximum yield of alcohol mediated Binding
100 μg
Single liquid carrying capacity of column
700 μl
Minimum elution volume
30 μl
Withstand centrifugal force
12,000 x g
Centrifuge
Small high speed centrifuge (2ml)
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silicagel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No.
Product Name
Package
C13100
HiPure DNA Mini Column I (2 x GF/B)with 2ml Collection Tubes
1000/Bag
Purchase Guide
Item No.
Product Name
Membrane type/number of layers
Collection tubes
Plasmid DNA binding capacity (Physical adsorption)
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Document
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.