Propargyl-PEG4-thiol is a crosslinker containing a propargyl group and thiol group. The propargyl group can form triazole linkage with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry reactions. The thiol group reacts with maleimide, OPSS, vinylsulfone and transition metal surfaces including gold, silver, etc. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
Propargyl-PEG4-thiol is a crosslinker containing a propargyl group and thiol group. The propargyl group can form triazole linkage with azide-bearing compounds or biomolecules via copper catalyzed Click Chemistry reactions. The thiol group reacts with maleimide, OPSS, vinylsulfone and transition metal surfaces including gold, silver, etc. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
D3144 HiPure Soil/Stool DNA 96 Kit
Product Info
Document
Product Info
Introduction
This product allows rapid and reliable isolation of high-quality genomic DNA from various soil and stool samples. Up to 100mg stool sample and 500 mg soil samples can be processed in 60 minute. The system combines the reversible nucleic acid binding properties of HiPure matrix with the speed and versatility of spin column technology to eliminate PCR inhibiting compounds such as humic acid from soil samples. Purified DNA is suitable for PCR, restriction digestion, and next-generation sequencing. There are no organic extractions thus reducing plastic waste and hands-on time to allow multiple samples to be processed inparallel.
Details
Specifications
Features
Specifications
Main Functions
Isolation DNA from 200-500mg soil, 50-100mg stool, or 100-500mg other environmental samples using 96 plate
Soil/Stool sample is homogenized and then treated in a specially formulated buffer containing detergent to lyse bacteria, yeast, and fungal samples. Humic acid, proteins, polysaccharides, and other contaminants are removed using our proprietary Absorber Solution. Binding conditions are then adjusted and the sample is applied to a DNA Mini Column. Two rapid wash steps remove trace contaminants and pure DNA is eluted in low ionic strength buffer. Purified DNA can be directly used in downstream applications without the need for further purification.
Advantages
Fast – several samples can be extracted in 40 minutes (after digestion)
High purity – the purified DNA can be directly used in various downstream applications
Good repeatability – silica technology can obtain ideal results every time
High recovery – DNA can be recovered at the level of PG
Kit Contents
Contents
D314401
D314402
D314403
Purification Times
1 x 96 Preps
4 x 96 Preps
20 x 96 Preps
HiPure DNA Plate
1
4
20
96 Well Plate (2.2ml)
1
4
20
1.6ml Collection Plate
1
4
20
0.8ml Collection Plate
1
4
20
2ml Bead Tubes
100
400
2000
Buffer SOL
100 ml
360 ml
2 x 900 ml
Buffer SDS
10 ml
36 ml
180 ml
Reagent DX
1 ml
1.8 ml
9 ml
Buffer PS
20 ml
80 ml
400 ml
Absorber Solution
20 ml
80 ml
400 ml
Buffer GDP
150 ml
500 ml
3 x 900 ml
Buffer GW2*
50 ml
100 ml
4 x 200 ml
Buffer AE
30 ml
120 ml
500 ml
Storage and Stability
Absorber Solution should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
This product allows rapid and reliable isolation of high-quality genomic DNA from various soil and stool samples. Up to 100mg stool sample and 500 mg soil samples can be processed in 60 minute. The system combines the reversible nucleic acid binding properties of HiPure matrix with the speed and versatility of spin column technology to eliminate PCR inhibiting compounds such as humic acid from soil samples. Purified DNA is suitable for PCR, restriction digestion, and next-generation sequencing. There are no organic extractions thus reducing plastic waste and hands-on time to allow multiple samples to be processed inparallel.
The series of DNA Size Selection Kits (Magnetic Beads) were developed for DNA size selection using magnetic beads. A total of 11 kits are available, with different selection ranges spanning from 50 bp to over 10 kb. The kits provide a simple and quick approach for the enrichment of a specific range of DNA fragments. The kit workflow allows double-sided or single-sided size selection for specific size cutoffs.
Gel images of different ranges of size selection. Sheared human genomic DNA was used as input.
.
DNA size selection is a selective capture of DNA fragments of a specific range of size for next-generation sequencing (NGS) library preparations, PCR, ChIP assay, DNA ligations, endonuclease digestions, adapter removal, and other genomics and molecular biology applications. DNA size selection is preferred after NGS library prep in most of the cases. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads technology uses paramagnetic particles, also known as SPRI (Solid Phase Reversible Immobilization) beads, to bind DNA reversibly and selectively. DNA fragments can be size-selected and purified by changing the properties of the magnetic beads or SPRI beads. The magnetic beads can easily separate the beads-binding DNA from the contaminants and unwanted components in the samples. The samples after DNA size selection are free of contaminants such as buffer components, enzymes, proteins, salts, dNTPs, primers, and adapters. Our proprietary magnetic beads reagents improve yield, selectivity, and reproducibility.
Specific DNA fragments at a certain length range can be purified simply using magnetic separation with different beads components, avoiding tedious and time-consuming gel extraction and column-based purification. The magnetic beads method is popular for common DNA size selection, including library size selection. The first beads-binding step, referred to as the right-side clean-up, removes large DNA fragments. The large DNA fragments are bound to the beads and are discarded. The desired DNA fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-binding, referred to as the left-side clean-up. The double-size selected DNA fragments are eluted after ethanol rinsing.
DNA size selection with dual clean-ups.
.
A single clean-up is needed for DNA size selection with large fragments. In this case, only the large DNA fragments are bound to the beads. The selected larger DNA fragments are eluted after ethanol rinsing.
DNA size selection with single clean-up for >5 kb and >10 kb DNA.
.
Features of DNA size selection and library size selection
High specificity and high recovery of size selection
11 selection ranges are available, including 5 ranges for NGS library size selection
50-100 bp
100-200 bp
200-500 bp
250-350 bp: ideal for illumina PE100 sequencing
300-450 bp: ideal for illumina PE150 sequencing
450-750 bp: ideal for illumina PE300 sequencing
500-1000 bp
1-3 kb
1-5 kb
>5 kb: ideal for long-read sequencing
>10 kb: ideal for long-read sequencing
Fast and simple
20-min protocol
No gel purification required
No columns required
No centrifugation required
Efficient removal of contaminants and unwanted components
Purification and enrichment of intact exosomes from plasma, serum, urine, cell culture media and saliva in less than 30 minutes.
Versatile sample input ranging from 50 µL to 10 mL
Plasma/Serum Exosome Purification Mini Kit (50 µL – 1 mL Plasma/Serum)
Plasma/Serum Exosome Purification Midi Kit (1 mL – 4 mL Plasma/Serum)
Plasma/Serum Exosome Purification Maxi Kit (4 mL – 10 mL Plasma/Serum)
Exosome purification is based on Norgen’s proprietary resin separating matrix through exosomes’ surface proteins.
No precipitation reagents, overnight incubation, protease or coagulant treatments required
No time-consuming ultracentrifugation, filtration or special syringes required
Purify intact exosomes with a size ranging from 40-200 nm depending on sample input type
Purified exosomes are compatible with functional studies.
Purified exosomes are free from any RNA-binding proteins
Purified exosomes are compatible with NanoSight® or Electron Microscopy for assessing the approximate exosome size range and concentration.
Exosomal RNA can be extracted from the purified exosomes using Norgen’s Exosomal RNA Purification technology or any other RNA extraction method.
The Plasma/Serum Exosome Purification Kits provide a fast, reliable and convenient method to purify and enrich for intact exosomes from different plasma/serum sample volumes ranging from 50 µL to 10 mL. These kits also allow for the purification of intact extracellular vesicles (EVs) from different plasma/serum sample volumes, and these EVs are ready for any downstream application. The purification is based on Norgen’s proprietary resin.
These kits provide a clear advantage over other available methods since they do not require any special instrumentation, ultracentrifugation, precipitation reagents or any protease treatments. More importantly, the purified exosomes will not be contaminated with any other RNA-binding proteins that may contaminate your exosomal RNA, which is essential if studying exosomal transcripts.
NanoSight® Analysis
Exosomes enriched with Norgen’s Plasma/Serum Exosome Purification Kits can be analyzed using NanoSight® for assessing the approximate exosome size range and concentration
Exosomal RNA Analysis
To purify exosomes and isolate exosomal RNA, choose the Plasma/serum Exosome Purification and RNA isolation kits. The protocol is divided into 2 parts and an aliquot of purified exosomes can be taken for applications like NTA/TEM etc. before processing them for RNA isolation. Or you can use the Exosomal RNA Isolation Kit if you’ve already purified exosomes using a Norgen kit or another method. . Exosomal RNA isolation is based on Norgen’s proprietary resin without the need for phenol extractions or carrier RNA. This RNA is ideal for gene expression analysis using RT-qPCR, microarray, or NGS and for biomarker discovery.
Variable depending on the plasma/serum input volume
Time to Complete 10 Purifications
15 – 30 minutes
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Important Note This kit is suitable for the purification of exosomes from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.