Lyophilized format designed for room temperature shipping
Available in TaqMan format for analysis
Norgen’s Vibrio cholerae TaqMan PCR Lyophilized Kit is designed for the detection of Vibrio cholerae specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s Vibrio cholerae TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of Vibrio cholerae specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
All kit components should be stored at -20°C upon arrival.
Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
Component
Cat. TM38550L (100 preps)
Cat. TM38510L (100 preps)
MDx TaqMan 2X PCR Master Mix (Lyo)
4 x 350 μL
–
Vibrio cholerae Primer & Probe Mix (Lyo)
280 μL
280 μL
Vibrio cholerae Positive Control (Lyo)
150 μL
150 μL
Nuclease-Free Water (Negative Control)
3 x 1.25 mL
1 x 1.25 mL
Product Insert
1
1
Other Products
Preserved Blood RNA Purification Kit II (for use with PAXgene Blood RNA Tubes)
Product Info
Document
Product Info
Overview
Compatible with PAXgene Blood RNA Tubes
Isolate true total RNA including siRNA and microRNA
No phenol extractions
Purify high-quality RNA in 30 minutes
Purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s Preserved Blood RNA Purification Kit II provides a rapid method for the isolation and purification of total RNA from blood that has been preserved using PAXgene Blood RNA Tubes*. The kit purifies all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA (miRNA) and small interfering RNA (siRNA). The RNA is preferentially purified from other cellular components such as proteins, without the use of phenol or chloroform.
Purification is based on spin column chromatography using Norgen’s proprietary resin as the separation matrix. Norgen’s proprietary resin provides superior affinity to the full size range of RNA molecules, resulting in large and small RNA (miRNA) purification with better linearity and sensitivity. The purified RNA is of the highest integrity, and can be used in a number of downstream applications including real time RT-PCR, RT-PCR, Northern blotting, RNase protection and primer extension, expression profiling, miRNA cloning and amplification and Next Generation Sequencing.
* PAXgene Blood RNA Tubes are a product of PreAnalytiX GmbH. PAXgene Blood RNA Tubes are not provided.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment. The DNase I should be stored at -20°C.
1. The instantaneous centrifugal function rises to the maximum speed for about 6 seconds, allowing for rapid detachment of hanging droplets from the wall;
2. Faster acceleration and deceleration rate, required to complete the experiment in a shorter time;
3. Door cover protection, overspeed and imbalance detection system, capable of real-time monitoring of the centrifugal process, ensuring the safe operation of the instrument; When the operation ends, an error occurs, or an imbalance occurs, the sound signal prompts, and the operation stops at the same time. The LCD displays the result code
Host Parameters
Product model
Mini-3
Input power supply
DC24V/2.75A
Input power
55W
Motor/Drive Method
DC24V brushless DC variable frequency motor
Display method
High brightness LCD screen
Effective centrifugal time
1-99min.1-59sec
speed
300~3000±15rpm
Speed step increase
10rpm
Maximum capacity
2 *96 well PCR plates/ELISA plates
MAX. RCF
608 xg
Misoperation/alarm failure
Sound prompt+display code
weight
3.9Kg
Noise
60dB (A)
Fastest acceleration time
<6s
Fastest deceleration time
<5s
Permissible ambient temperature/relative temperature
+5-40°C/80%
Document
The micro porous plate centrifuge adopts international advanced design concepts and manufacturing technology, with a smooth and beautiful appearance, compact and stable structure, adhering to the advantages of high universality and easy operation. It also has the functional characteristics of “smooth start” and “smooth braking”; This micro porous plate centrifuge is very suitable for 96 or 384 well and small capacity micro porous plates, as well as various standard PCR micro porous plates with or without skirts .
Collagen is a fundamental component of the extracellular matrix, and the predominant protein in animals, constituting around 30% of total protein mass. A glycoprotein, it is well known for its triple helical structure. This is formed from three polypeptide α-chains with Gly-X-Y repeating residues (Gly for Glycine, X for proline, and Y for hydroxyproline).
Types of Collagen
Over 28 types of collagens have been identified, with Type I collagen being the most abundant. It’s prevalent in ligaments, tendons, skin, and bone tissue. Its mature, insoluble form grants it remarkable strength, making it vital for the mobility of organisms. Collagen also has biochemical functions, influencing cell growth, proliferation, and differentiation.
This version of the kit is designed to detect and measure SOLUBLE forms of collagen. Chose the Sircol Insoluble collagen kit if you need to analyse INSOLUBLE collagen.
Applications of Collagen
Collagen, with its diverse properties, finds utility in various industries. It plays a role in medicine for wound healing and has an expanding role in tissue engineering and cell culture for biomedical purposes. It’s gaining popularity in the cosmetic industry for skin rejuvenation and is used in chemical formulations and the food industry as a functional food supplement and additive.
How does Sircol 2.0 detect collagen?
The Sircol 2.0 dye reagent includes Sirius Red, a linear anionic dye with sulfonic acid side chains. This reagent is specially formulated to bind to the Gly-X-Yn helical structure of soluble collagen under assay conditions.
*The improved formulation of Sircol 2.0 dye enables a greater degree of dye-collagen specificity (compared to our previous S1000 assay kit).
Overview of the Sircol 2.0 assay process:
Step 1. Prepared samples are placed in the wells of the assay microplate, together with Sircol Dye Reagent. After 30 minutes mixing, any collagen-dye complexes will form as a precipitate. These are collected on the base of the microplate wells by centrifugation.
Step 2. Unbound dye is removed by gentle aspiration, followed by a rinse with Plate Wash Reagent.
Step 3. Following further centrifugation, collagen-bound dye is eluted by incubation with a Dye Release Reagent. Eluted dye is detected ‘in-situ’ by spectrophotometric analysis of the microplate at 556nm.
Step 4. The collagen content of unknown samples can be quantified by comparison against a calibration curve, prepared using the Collagen Reference Standard supplied with the kit.
A list of suggested sample types can be found under the ‘Assay Specification‘ tab.
Colorimetric Detection (556nm) (Endpoint), Requires a microplate centrifuge.
Measurements per kit
96 in total (allows a maximum of 41 samples to be run in duplicate alongside a standard curve).
Suitable Samples
Soluble* collagens from mammalian**:
In-vivo: Tissues, cartilages and fluids.
In-vitro: Extracellular matrices / Conditioned media from 2D/3D culture environments.
The straightforward sample processing and analysis of Sirco 2.0 make it a good alternative to conventional hydroxyproline analysis.
*Prior salt/acid/acid-pepsin extraction may be necessary to release soluble collagen.
**Sircol 2.0 is primarily designed for use with in-vivo / in-vitro samples of mammalian origin. Collagens originating from other taxonomic groups and kingdoms can also be analysed. See note on p6 of manual for further information.
Precautions
This kit is designed for research use only. Not for use in diagnostic procedures. Kit requires access to a microplate centrifuge* (see note below), as well as a spectrophotometer/colorimeter capable of absorbance detection at 556nm. Specific sample preparation protocols may require customer to provide further reagents, consult assay manual for further information.
*As a minimum, we recommend that the centrifuge can centrifuge a 96-well microplate at 400 x g for 120 minutes. Higher speed centrifuges are recommended (up to a maximum of 2000 x g), allowing a reduction in centrifuge time.
Sircol 2.0 kit contents:
1. Dye Reagent (1x20ml)
2. Collagen Reference Standard (1x5ml, 200µg/ml of soluble Bovine collagen)
3. Plate Wash Reagent (1x28ml)
4. Collagen Concentration Reagent (1x25ml)
5. Neutralisation Reagent (1x8ml)
6. Dye Release Reagent (1x25ml)
7. Assay Microplate (1×96-wells)
8. Microplate Seals (6x)
9. Documentation (QuickStart Guide / Manual / Certificate of Analysis)
NB: Additional reagents may be required for sample preparation prior to assay. Consult manual or contact us for further details. This kit requires the use of a microplate centrifuge, capable of centrifuging a 96-well microplate at 400 x g for 120 minutes. Higher speed centrifuges are recommended (up to a maximum of 2000 x g), allowing a reduction in centrifuge time.
Document
Experience user-friendly detection & measurement of Soluble Collagen with Sircol™ 2.0! Our latest kit simplifies collagen quantification within in-vivo / in-vitro samples. Sircol 2.0 offers enhanced sensitivity and accuracy compared to our previous Sircol kit.