Fractionate leukocytes from whole blood in minutes with provided RBC Lysis Buffer
Isolate total RNA, including microRNA, without phenol
Rapid and convenient spin-column format and 96-well plate for high throughput applications
Purified RNA is ready for any downstream application including RT-PCR, qRT-PCR, NGS, arrays and more. Find out more information on Norgen’s NGS services
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a rapid method for the isolation and purification of total leukocyte (white blood cell) RNA from mammalian blood samples. These kits are supplied with an RBC (red blood cell) Lysis Buffer for selective removal of red blood cells and fractionation of leukocytes by centrifugation. Isolation of leukocyte RNA results in improved expression profiling and other downstream applications by removing the masking effects of some RNAs which are very abundant in whole blood, such as globin mRNAs. These kits are able to isolate total leukocyte RNA, including both large mRNA and all small RNA species containing microRNA (miRNA) and small silencing RNA (siRNA). The purified RNA is of the highest quality and can be used in a number of downstream applications.
Leukocyte RNA Purification Kit (Spin Column)
This kit provides a rapid method for the isolation and purification of total leukocyte RNA from mammalian blood samples in 40 minutes. Allowable blood input ranges from 10 μL to 2 mL or 3 x 106 Leukocytes
Leukocyte RNA Purification Plus Kit (Plus)
Norgen’s Leukocyte RNA Purification Plus Kit provides a rapid method for the isolation and purification of total leukocyte (white blood cell) RNA from up to 3 mL of mammalian blood samples. Complete 10 purifications in as little as 40 minutes.
Purification is based on 96-well column chromatography using Norgen’s proprietary resin as the separation matrix. Purification can be performed using either a vacuum manifold or centrifugation. Norgen’s kit allows for the isolation of total leukocyte RNA, including all small RNA species. The purified RNA is of the highest quality and can be used in a number of downstream applications including real time PCR, reverse transcription PCR, northern blotting, RNase protection and primer extension, and expression array assays. Allowable blood input ranges from 10 μL to 1 mL or 1.5 x 106 Leukocytes.
Average Yield Human Blood (500 μL) Hamster Blood (100 μL)
1.5 μg 2.5 μg
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. The RBC Lysis Buffer should be stored at 4°C upon arrival.
Component
Cat. 21200 (50 preps)
Cat. 21250 (50 preps)
Cat. 37800 (2 x 96 preps)
RBC Lysis Buffer
2 x 100 mL
2 x 1 L
2 x 90 mL
Buffer RL
30 mL
30 mL
–
Binding Solution
–
–
2 x 40 mL
Wash Solution A
38 mL
38 mL
–
Wash Solution
–
–
2 x 30 mL
Elution Solution A
6 mL
6 mL
–
Elution Solution
–
–
2 x 20 mL
Enzyme Incubation Buffer
–
6 mL
1
DNase I
–
1 Vial
–
Mini Spin Columns
50
–
–
Lysate Homogenization Column
–
50
–
Single Cell RNA Column
–
50
–
RBC Lysis 96-Well Plate
–
–
2
96-Well Filter Plate
–
–
2
Adhesive Tape
–
–
4
Collection Tubes
50
100
–
96-Well Collection Plate
–
–
2
Elution Tubes (1.7 mL)
50
50
–
96-Well Elution Plate
–
–
2
Product Insert
1
1
1
Other Products
65L/ 90L/ 110L High-pressure Steam Autoclave
Product Info
Document
Product Info
Safety Features
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.
The kit includes BR Dye, BR Dilution Buffer, and two DNA Standards. The assay is accurate for DNA concentrations from 100 pg/µL to 1000 ng/µL, and is highly selective for double-stranded DNA over RNA.
Features
Kit was optimized for use with the Qubit® Fluorometer
Uses the Qubit® dsDNA Broad Range assay setting
Linear range is 2-1000 ng dsDNA
Great saving since the kit cuts the costs by 60%
DNA selectivity and sensitivity. A series of input DNA (200, 400, 600, 800, and 1000 ng) was used with or without RNA contamination.
N-(Amine-PEG8)-N-bis(PEG8-Propargyl) is a trifunctional linker containing an amino group and two terminal alkynes. These alkynes are frequently used in copper (I) click reactions with azides to form stable triazole linkages, while the primary amine is reactive towards carboxylic acids and other carbonyl compounds such as NHS esters, aldehydes or ketones.
Document
N-(Amine-PEG8)-N-bis(PEG8-Propargyl) is a trifunctional linker containing an amino group and two terminal alkynes. These alkynes are frequently used in copper (I) click reactions with azides to form stable triazole linkages, while the primary amine is reactive towards carboxylic acids and other carbonyl compounds such as NHS esters, aldehydes or ketones.