The Multiplexing Index Primers contain primer mix for multiplexing library samples for Next Generation Sequencing (NGS) on the illumina platform. Multiplexing of NGS library samples will reduce sequencing costs by pooling multiple NGS libraries into a single flow cell lane.
Detail
The Multiplexing Index Primers contain primer mix for multiplexing library samples for Next Generation Sequencing (NGS) on the illumina platform. Multiplexing of NGS library samples will reduce sequencing costs by pooling multiple NGS libraries into a single flow cell lane.
With library multiplexing, unique index sequence is added to individual sample during NGS library preparation. Therefore, each DNA molecule can be identified after pooling of multiple samples based on the index information they have.
Each of our index primers contains a unique index sequence with 6 bases that can be used to identify libraries. Library multiplexing up to 48 samples is possible.
Multiplexing Index Primers (illumina platform): Even distribution of 48 samples using index primers. 48 libraries were made using the BioDynami NGS DNA Library Prep Kit (Cat. # 30009) and the BioDynami Multiplexing Index Primers (Cat. # 30072). Libraries were pooled at equal concentration and sequenced on the illumina HiSeq 2500. The numbers of reads from 48 libraries were analyzed.
List of index sequence for the primers (each of the index primer mix contains universal primer and one of the index primers). Index number and the index sequence are listed.
Sequence of the final library with index location:
Other Products
R4171 HiPure Viral RNA Kit
Product Info
Document
Product Info
Introduction
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.
Details
Specifications
Features
Specifications
Main Functions
Extract viral RNA from 140μl cell-free samples
Applications
RT-PCR, Northern hybridization, and various virus detection
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Cell-free body fluid or culture medium
Sample amount
140μl
Elution volume
≥15μ
Time per run
≤25 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such as guanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein and other impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
The sample is homogenized and lysed in the lysate, and RNA is released into the lysate. The high concentration of guanidine isothiocyanate contained in the lysate denatured and inactivated endogenous or exogenous RNase, while RNA is protected from degradation. The lysate is centrifuged to remove insoluble impurities. After adding ethanol to adjust the binding conditions, it is transferred to the column for filtration. RNA is adsorbed on the membrane of the column, while protein is removed without adsorption. The column is washed with buffer VHB to remove protein and other impurities, washed with buffer RW2 to remove salt. Finally the RNA is eluted by RNase free water. The eluted RNA can be directly used in RT-PCR, Northern blot, poly-A purification, in vitro translation, etc.
Advantages
Fast – several samples can be extracted in 20 minutes by column method
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
High yield – carrier RNA contained in the product maximize the recovery of trace nucleic acid
Kit Contents
Contents
R417102
R417103
Purification Times
50 Preps
250 Preps
HiPure Viral Micro Columns
50
250
2ml Collection Tubes
100
500
Buffer VRL
50 ml
200 ml
Carrier RNA
310 µg
3 x 310 µg
Buffer VHB*
13 ml
110 ml
Buffer RW2*
20 ml
2 x 50 ml
Nuclease Free Water
10 ml
30 ml
Storage and Stability
Carrier RNA should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under theseconditions
Document
Hipure viral RNA kit is suitable for purifying viral RNA from samples such as cell-free body fluid or culture medium. The kit is based on silica gel column purification technology. It requires no toxic phenol chloroform extraction and time-consuming alcohol precipitation in the extraction. The whole extraction process takes only 25 minutes. The kit is suitable for extracting viral RNA from 1-140µl cell-free fluid samples such as serum, plasma, cell-free body fluid or culture medium. The product has successfully extracted hepatitis B A/C, hepatitis C RNA, SARS and HIV. The obtained RNA can be directly used for RT-PCR, Northern hybridization and virus detection.
Perforated heat sealing film which is optically clear. This seal has 3 mm slits for gas transfer; is suitable for insect studies and seed storage too.
Heat sealing is a quick and cost effective method of plate sealing
Our ClearASeal Perf Heat Seal is based on our ClearASeal Peel, with the addition of 3 mm slits across the width of the seal
These slits render the seal gas permeable, whilst retaining evaporation to a minimum, compared to the use of lids
The ClearASeal Perf Heat Seal is compatible with polypropylene, polyethylene, polystyrene and cyclic olefin copolymer (COC) plates
The Seal has a wide seal integrity temperature range, from -80 °C to 110 °C
It can be used for insect and seed storage, as it enables gas exchange, whilst providing an inert surface with no adhesive to interfere with the well contents
This seal is available as sheets, for use with manual and semi-automated sealers, such as our HeatASeal 500 Sealing Machine
Also available in roll format compatible with specified automated heat sealers, such as our Wasp or Chameleon XT
Document
Perforated heat sealing film which is optically clear. This seal has 3 mm slits for gas transfer; is suitable for insect studies and seed storage too.