For the detection of the SARS-CoV-2 variants with the N501Y mutation (UK, South Africa and Brazil)
Rapid detection of specific detection profiles
High priming efficiency
Sensitive to < 100 copies of target
Positive copy number standard curve for quantification
Accurate controls to confirm findings
96 reactions, includes master mix
Our SNPsig® kits use our own proprietary genotyping method to enable the identification of SARS-CoV-2 variants of concern. These products can be used on any real-time PCR machine using familiar protocols, whilst resulting in exceptional genotyping data.
Positive control templates for wild-type and variants are supplied in every kit to make data interpretation simple.
Our SNPsig® technology provides an alternative to sequencing as well as S gene target failure (SGTF) that enables scientists to analyse and monitor these specific genomic mutations. Our kits can provide a pivotal role in screening for SARS-CoV-2 variants for the purpose of genomic surveillance and studies.
Other Products
D3146 HiPure Bacterial DNA Kit
Product Info
Document
Product Info
Introduction
This product provides fast and easy methods for purification of total DNA for reliable PCR and southern blotting. Total DNA can be purified from bacterial culture, body fluids, food and fermentation.
Details
Specifications
Features
Specifications
Main Functions
Isolation bacterial DNA from cultures, food and other samples
Applications
PCR, southern blot and enzyme digestion, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Culture medium, swab, parasitic blood, tissue,sputum, etc.
Sample amount
Bacterial culture medium: 0.5-2 mlTissue samples: 50-100 mg Whole blood / cell suspension: 0.5-1 ml Viscous secretion: 0.1-1 g
Elution volume
≥30μl
Time per run
≤40 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while proteinis not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mmTris, pH9.0, 0.5mm EDTA). This product carries 0.1-0.2mm acid glass beads, which can improve the wall-breaking effect of lysozyme resistant bacteria, the success rate and DNA yield through physical bead grinding.
Advantages
Fast – several samples can be extracted in 40 minutes (after digestion)
High purity – purified DNA can be directly used in various downstream applications
Good repeatability – silica technology can obtain ideal results every time
High recovery – DNA can be recovered at the level of PG
Broad spectrum – it can deal with a variety of bacteria, including Gram-positive bacteria that are difficult to disrupt
Sufficient components – this kit has carried lysozyme, protease K, RNase A and glass beads
Kit Contents
Contents
D314602
D314603
Purification Times
50 Preps
250 Preps
Hipure DNA Mini Columns I
50
2 x 125
2ml Collection Tubes
50
2 x 125
Glass Beads (0.1~0.2mm)
20 g
100 g
Buffer P1
20 ml
100 ml
Buffer DL
15 ml
80 ml
Buffer GW1
22 ml
88 ml
Buffer GW2
12 ml
50 ml
Lysozyme
60 mg
300 mg
Proteinase K
24 mg
120 mg
Protease Dissolve Buffer
5 ml
15 ml
Buffer AE
15 ml
60 ml
Storage and Stability
Lysozyme and Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
This product provides fast and easy methods for purification of total DNA for reliable PCR and southern blotting. Total DNA can be purified from bacterial culture, body fluids, food and fermentation.
The Opentrons Flex HEPA/UV Module enables you to run sensitive contamination-prone applications. It removes 99.99% of 0.3 μm DNA-containing particulates and biological contaminants like bacteria, fungi, and other microorganisms from the air, creating a clean work environment inside the Opentrons Flex.
Document
The Opentrons Flex HEPA/UV Module enables you to run sensitive contamination-prone applications. It removes 99.99% of 0.3 μm DNA-containing particulates and biological contaminants like bacteria, fungi, and other microorganisms from the air, creating a clean work environment inside the Opentrons Flex.
Microcystin are a class of hepatotoxins produced by blue-green algae such as Microcystis aeruginosa. Microcystin-LR is the most common of the over 50 different congeners. Cyanobacteria can produce microcystin in large quantities during an algae bloom which then pose a major threat.
This kit can be used for Congener-Independent quantitative test of Microcystin in liquid samples such as drinking, ambient and waste water and algal cultures.
Additional Quality Control, Calibration Verification, and Spiking Solution materials can be obtained separately in optional Supplemental Pack for Method 546 (catalog # EL2024-Q).
Microcystin-LR
Informational sign postings about HABs at recreational waters: < 6 μg/L
Recreational public health advisory: 6 μg/L
Elevated recreational public health advisory (e.g. no contact): 20 μg/L
EPA 10-day drinking water health advisories:
Do Not Drink – 0.3 μg/L for bottle fed infants and preschool children, pregnant and nursing woman, elderly immunocompromised and liver conditions.
Do Not Drink – 1.6 μg/L for school-age children to adults.
Do not Use – 20 μg/L
Document
Format: 96-well microtiter plate (12 test strips of 8 wells)
Standards: 0 | 0.15 | 0.4 | 1 | 2 | 5 ppb
Incubation Time: 75 Minutes
Compatible for use with US EPA Method 546