DL6MB large capacity refrigerated centrifuge
Features:
1. Widely used in the field of blood bank, pharmaceutical factory and laboratory.
2. Brushless frequency motor, in great torque, free maintenance, no powder pollution, quick in speed up and down.
3. Digital display which indicates the program, speed, time,RCF, temperature.
4. Micro computer control, there are 10 kinds of program and 10 kinds of acceleration and deceleration for your choice.
5. There are 6 kinds of rotors for your choice.
6. Electric lid lock, compact design, super speed and imbalance protection.
7. The centrifuge body is made of high-quality steel, safe and reliable.
DL6MB Technical Parameter:
Max. Speed | 6000rpm |
Max. RCF | 6600*g |
Max. Capacity | 6×1000ml(6*500ml blood bag) |
Time Range | 0~9h59min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 55 |
Temperature | -20-40 degrees |
Acc/Dcc | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Voltage(V/Hz) | AC 220V 50HZ/60HZ |
Size (W x D x Hmm) | 800×675×830mm |
Net Weight(Kg) | 310KG |
Certificates | CE,ISO & Calibration report are available |
Matched Rotors for DL6MB
Order No. | Rotor No. | Max Speed (rpm) | Max Volume(ml) | Max.RCF(×g) |
No30298 | Swing Rotor | 4200 | 6×1000ml | 5100 |
NO30221 | Angle Rotor | 6000 | 4×300ml | 5390 |
NO30222 | Angle Rotor | 6000 | 6×300ml | 5660 |
NO30223 | Angle Rotor | 6000 | 6×500ml | 6600 |
Widely used in the field of blood bank, pharmaceutical factory and laboratory.
Listeria monocytogenes have emerged as significant foodborne pathogens that pose a serious public health problem. As the causative agent of Listeriosis, L. monocytogenes has the highest rate of fatality rate among all foodborne pathogens. L. monocytogenes is a facultatively intracellular, Gram-positive bacterium that could survive high and low temperatures, low pH. It is a rare causative agent of mastitis in cow. However, due to its ability to resist various food processing technologies as well as to grow at low temperature, L. monocytogenes is know to be associated with both raw and pasteurized milk, as well as dairy products such as cheese. As little as 1000 organisms may cause the disease with pregnant, new-born, and immunocompromised individuals the most susceptible.
Listeria monocytogenes TaqMan PCR Kit, 100 reactions
Listeria monocytogenes TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
Component | Cat. TM30450 (100 preps) | Cat. TM30410 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
Listeria monocytogenes Primer & Probe Mix | 280 μL | 280 μL |
Listeria monocytogenes Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |
K-ACETGK
SKU: 700004257
110 mL of prepared reagent (e.g. 500 assays of 0.22 mL)
Content: | 110 mL of prepared reagent (e.g. 500 assays of 0.22 mL) |
Shipping Temperature: | Ambient |
Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
Stability: | > 2 years under recommended storage conditions |
Analyte: | Acetic Acid |
Assay Format: | Auto-analyser |
Detection Method: | Absorbance |
Wavelength (nm): | 340 |
Signal Response: | Increase |
Linear Range: | up to 1.8 g/L of acetic acid per assay |
Limit of Detection: | ~ 10 mg/L |
Reaction Time (min): | 8 min at 25oC or 5 min at 37oC |
Application examples: | Wine, beer, fruit and fruit juices, soft drinks, vinegar, vegetables, pickles, dairy products (e.g. cheese), meat, fish, bread, bakery products (and baking agents), ketchup, soy sauce, mayonnaise, dressings, paper (and cardboard), tea, pharmaceuticals (e.g. infusion solutions), feed and other materials (e.g. biological cultures, samples, etc.). |
Method recognition: | Improved method |
The Acetic Acid GK format test kit is for use with auto-analysers and is suitable for the specific measurement and analysis of acetic acid (acetate) especially in wines, fruit juices, beverages and food products.
As part of Megazyme’s overall commitment to providing the highest quality products, we have developed this acetic acid kit that provides a specific and rapid assay for use with auto-analysers. The kit assay is based on the conversion of NAD+ to NADH and therefore provides a positive reaction (increase in absorbance) which offers a more robust assay.
The reagents, as supplied, are stable for a minimum of 2 years and the prepared reagents are stable for a minimum of 1 week (on-board stability). In addition, the prepared reagents can be stored frozen for longer term stability (see K-ACETGK Booklet for more details).
View more of our acetic acid and organic acid assay kits.
Advantages
The Acetic Acid GK format test kit is for use with auto-analysers and is suitable for the specific measurement and analysis of acetic acid (acetate) especially in wines, fruit juices, beverages and food products.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map